[object ObjectA spark discharge system was coupled to laser-induced breakdown spectroscopy (SD-LIBS) to improve sensitivity in the determination of P in fertilizers. A LIBS system consisting of a Q-switched Nd:YAG laser operating at 1064 nm and emitting pulses at 50 mJ with a fluence of 70 J cm-2 at the focal point was used. Results of preliminary experiments suggested that the most appropriate wavelength to measure P was the P (I) line at 214.9 nm, which did not show interferences by Fe, Cu and Zn. The electrical discharge was provided by a homemade high-voltage electronic circuit consisting of two cylindrical tungsten electrodes at the optimized output voltage of 4.5 kV, with tips arranged at the optimal distances of 4 mm between them and 2 mm above the sample surface. To minimize the expected matrix effects calibration standards of P2O5 in the range of 4.8 and 33.3% were prepared by mixing various amounts of a phosphate rock reference material (SRM-120c) with a mixture of CaCO3, CaSO4, (NH2)2CO and KCl at a 1:1:1:1 mass ratio. The calibration curves obtained at a 4.5 kV SD-LIBS output voltage showed correlation coefficients >=0.993, RSD <=8% and LOQ 5.3% (m/m) P2O5. Data obtained by analyzing commercial samples by the proposed system were in good agreement, at 95% confidence level, with those obtained by using high-resolution continuum-source flame atomic absorption spectroscopy.

Determinations of phosphorus in fertilizers by spark discharge-assisted laser-induced breakdown spectroscopy

Senesi GS;
2018

Abstract

[object ObjectA spark discharge system was coupled to laser-induced breakdown spectroscopy (SD-LIBS) to improve sensitivity in the determination of P in fertilizers. A LIBS system consisting of a Q-switched Nd:YAG laser operating at 1064 nm and emitting pulses at 50 mJ with a fluence of 70 J cm-2 at the focal point was used. Results of preliminary experiments suggested that the most appropriate wavelength to measure P was the P (I) line at 214.9 nm, which did not show interferences by Fe, Cu and Zn. The electrical discharge was provided by a homemade high-voltage electronic circuit consisting of two cylindrical tungsten electrodes at the optimized output voltage of 4.5 kV, with tips arranged at the optimal distances of 4 mm between them and 2 mm above the sample surface. To minimize the expected matrix effects calibration standards of P2O5 in the range of 4.8 and 33.3% were prepared by mixing various amounts of a phosphate rock reference material (SRM-120c) with a mixture of CaCO3, CaSO4, (NH2)2CO and KCl at a 1:1:1:1 mass ratio. The calibration curves obtained at a 4.5 kV SD-LIBS output voltage showed correlation coefficients >=0.993, RSD <=8% and LOQ 5.3% (m/m) P2O5. Data obtained by analyzing commercial samples by the proposed system were in good agreement, at 95% confidence level, with those obtained by using high-resolution continuum-source flame atomic absorption spectroscopy.
2018
Inglese
139
322
326
http://www.scopus.com/record/display.url?eid=2-s2.0-85043451770&origin=inward
Sì, ma tipo non specificato
Spark discharge
LIBS
Phosphorus determination
Fertilizer analysis
1
info:eu-repo/semantics/article
262
Vieira A.L.; Silva T.V.; de Sousa F.S.I.; Senesi G.S.; Junior D.S.; Ferreira E.C.; Neto J.A.G.
01 Contributo su Rivista::01.01 Articolo in rivista
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/374951
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 50
  • ???jsp.display-item.citation.isi??? 48
social impact