The document describes the electrical model developed and the analyses carried out to evaluate the effect of breakdown events on MITICA Source components, with particular emphasis on the insulation between EG and PG components potential. The analyses results indicate that severe damage is expected during breakdown events with present design. Some possible mitigating measures are investigated and described both in terms of electrical effects and in terms of technical feasibility.

UPDATE OF THE MITICA INTEGRATED MODELLING REPORT

A Pesce;
2012

Abstract

The document describes the electrical model developed and the analyses carried out to evaluate the effect of breakdown events on MITICA Source components, with particular emphasis on the insulation between EG and PG components potential. The analyses results indicate that severe damage is expected during breakdown events with present design. Some possible mitigating measures are investigated and described both in terms of electrical effects and in terms of technical feasibility.
2012
Istituto gas ionizzati - IGI - Sede Padova
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/178736
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact