The deliverable reports on the results obtained during the activities carried on in the tasks 3.2 Autoclave Sensorization and task 3.3 Thermal Characterization Of The Autoclave Equipment Under Standard Manufacturing Service. In particular: ? a Fiber optic sensors equipped thermal fluximeter has been designed, built and preliminary tested in laboratory based on the analysis performed in D 3.1, ? the Reglass autoclave has been sensorised with a fiber optic temperature monitoring system, ? the mapping of the convective heat exchange phenomena in the Reglass autoclave has been performed. Main quantitative results are: ? a novel technology for thermal qualification of the autoclave systems has been delivered to the Reglass company that comprises both a methodology and an hardware system, ? the needed thermal mapping of the Reglass autoclave to be forwarded to the further studies related to the WP2 has been accomplished.

SCYPRI-Project Deliverable D3.2 - EXPERIMENTAL REPORT ON MAPPED SENSORIZED AUTOCLAVE DURING NORMAL OPERATIVE MODE AND COMPARISON WITH NUMERICAL PREDICTIONS

Alfonso Martone;Mauro Zarrelli;Vincenza Antonucci;Michele Giordano
2014

Abstract

The deliverable reports on the results obtained during the activities carried on in the tasks 3.2 Autoclave Sensorization and task 3.3 Thermal Characterization Of The Autoclave Equipment Under Standard Manufacturing Service. In particular: ? a Fiber optic sensors equipped thermal fluximeter has been designed, built and preliminary tested in laboratory based on the analysis performed in D 3.1, ? the Reglass autoclave has been sensorised with a fiber optic temperature monitoring system, ? the mapping of the convective heat exchange phenomena in the Reglass autoclave has been performed. Main quantitative results are: ? a novel technology for thermal qualification of the autoclave systems has been delivered to the Reglass company that comprises both a methodology and an hardware system, ? the needed thermal mapping of the Reglass autoclave to be forwarded to the further studies related to the WP2 has been accomplished.
2014
MATERIALI COMPOSITI E BIOMEDICI
Rapporto intermedio di progetto
composites
autoclave
FBG
heat transfer
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/313640
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact