The radiofrequency ion source NIO1 has an RF line composed by two strips of copper, air insulated, to connect the matching network to the RF load. In this document the results of a specific campaign aimed to characterize the electrical behaviour of this component are presented. In particular the results of measurement campaign with an impedance analyser are reported to evaluate the inductance and capacitance per meter of the NIO1 RF line. Furthermore results are compared with those obtained following the current literature and by a Finite Element approach.

NIO1: analyses on the RF transmission line

Recchia M;
2015

Abstract

The radiofrequency ion source NIO1 has an RF line composed by two strips of copper, air insulated, to connect the matching network to the RF load. In this document the results of a specific campaign aimed to characterize the electrical behaviour of this component are presented. In particular the results of measurement campaign with an impedance analyser are reported to evaluate the inductance and capacitance per meter of the NIO1 RF line. Furthermore results are compared with those obtained following the current literature and by a Finite Element approach.