This document represents deliverable D9.1 of the Specific Contract F4E-OFC-531-01 - Neutral Beam Test Facility Diagnostics, Task Order No.1: SPIDER Diagnostics #1. The final design of the Imaging diagnostic for SPID ER is reported, in particular the layout with inter faces, technical specification of components, description of integration and test procedures. The diagnostic comprises a set of cameras that will be used to look through fused silica viewports ins ide the vacuum vessel for inspection of the internal compon ents (beam source, STRIKE and beam dump) or as an imaging diagnostic to collect the light emitted by the beam interacting with the background gas. The specifications of the set of cameras are chosen to possibly serve both scopes. The diagnostic includes also an IR camera that looks at the external surface of the vacuum vessel to monitor variations of its temperature.

Final design and technical specification for procurement and installation of Imaging diagnostic

Pasqualotto R
2016

Abstract

This document represents deliverable D9.1 of the Specific Contract F4E-OFC-531-01 - Neutral Beam Test Facility Diagnostics, Task Order No.1: SPIDER Diagnostics #1. The final design of the Imaging diagnostic for SPID ER is reported, in particular the layout with inter faces, technical specification of components, description of integration and test procedures. The diagnostic comprises a set of cameras that will be used to look through fused silica viewports ins ide the vacuum vessel for inspection of the internal compon ents (beam source, STRIKE and beam dump) or as an imaging diagnostic to collect the light emitted by the beam interacting with the background gas. The specifications of the set of cameras are chosen to possibly serve both scopes. The diagnostic includes also an IR camera that looks at the external surface of the vacuum vessel to monitor variations of its temperature.
2016
Istituto gas ionizzati - IGI - Sede Padova
Rapporto finale di progetto
Neutral Beam Test Facility
NBTF
SPIDER
Neutral Beam Test Facility Diagnostics
SPIDER Diagnostics
IR cameras
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/324706