This document specifies the requirements, the interface sheet, the final and manufacturing design and manufacturing of the SPIDER Beam Dump Thermocouples with respect to SPIDER CODAS and INTERLOCK . T he SPIDER Beam Dump Thermocouples are defined as the thermocouples that are installed in the SPIDER long - pulse calorimeter, referred to as Beam Dump.

SPIDER Injector Plant System - Beam Dump Thermocouples - Requirements, Interface Sheet, Final and Manufacturing Design, and Manufacturing

Taliercio C;Brombin M;Zampiva E
2016

Abstract

This document specifies the requirements, the interface sheet, the final and manufacturing design and manufacturing of the SPIDER Beam Dump Thermocouples with respect to SPIDER CODAS and INTERLOCK . T he SPIDER Beam Dump Thermocouples are defined as the thermocouples that are installed in the SPIDER long - pulse calorimeter, referred to as Beam Dump.
2016
Istituto gas ionizzati - IGI - Sede Padova
Rapporto finale di progetto
Neutral Beam Test Facility
NBTF control
interlock and safety
SPIDER
SPIDER injector plant system