Deeply submerged towing experiments have been carried out for a full scale dummy towed hydrophone array. The model is made of modular sections able to reach a total length equal to 142 meter, the maximum one consistent with the basin. The various intermediate configurations tested, progressive in length, allowed to perform a good resistance prediction of the 192 meter long true array. The towing force necessary to tow the array at sea at 9 m/s results equal to 2600 N. The second target obtained is the determination of the scaled force to apply to the VDS during the following stability tests to be performed at the Circulating Channel. The towing force that will simulate the presence of the array is calculated by using the resistance coefficient correlation line obtained from the present tests. Finally the combined standard uncertainty uc for the array only configuration results equal to 0.9% of the measurement at the speed of 5 m/s.

Sono presentati i risultati delle prove di traino a quota profonda di un simulacro in scala 1:1 di Cortina Idrofonica. Il modello è stato realizzato in sezioni componibili fino a raggiungere una lunghezza massima compatibile con l'impianto sperimentale di 142 m. Le diverse configurazioni intermedie provate, a lunghezza crescente, hanno permesso di ottenere con buona approssimazione una previsione di resistenza della cortina vera, lunga 192 metri, per estrapolazione in lunghezza. La forza necessaria a trainare la cortina a 9 m/s in mare risulta essere pari a 2600 N. Il secondo obiettivo raggiunto è stato quello di determinare il tiro della cortina sul modello in scala di VDS nelle successive prove di assetto al canale di circolazione. La forza che può simulare la presenza della cortina è stata qui determinata individuando una linea di correlazione del coefficiente di resistenza, applicabile quindi per qualsiasi scala. Infine l'incertezza composta uc, valutata a 5 m/s nella configurazione solo cortina, risulta essere uguale allo 0.9% della misura.

Prove di Traino su modello di Cortina Idrofonica, Rapporto di Prova n° C.2605-15CT15-RAP01, TESTS No. 1 ÷ 6

Franco Di Cio';Marco Masia;Fabio CARTA;COPPOLA Giovanni;Alessandro DI COLA;Marco FORTUNATI;Alessandro Piazza;Giulio Orrico;Fabio Arrigo;Fiorello CUTINI CALISTI;Roberto Basti;Flavio OLIVIERI;Alberto Ugolini;Victor Santos Hugo;BONCI Ivana;Veraldo Maggi
2016

Abstract

Deeply submerged towing experiments have been carried out for a full scale dummy towed hydrophone array. The model is made of modular sections able to reach a total length equal to 142 meter, the maximum one consistent with the basin. The various intermediate configurations tested, progressive in length, allowed to perform a good resistance prediction of the 192 meter long true array. The towing force necessary to tow the array at sea at 9 m/s results equal to 2600 N. The second target obtained is the determination of the scaled force to apply to the VDS during the following stability tests to be performed at the Circulating Channel. The towing force that will simulate the presence of the array is calculated by using the resistance coefficient correlation line obtained from the present tests. Finally the combined standard uncertainty uc for the array only configuration results equal to 0.9% of the measurement at the speed of 5 m/s.
2016
Istituto di iNgegneria del Mare - INM (ex INSEAN)
Sono presentati i risultati delle prove di traino a quota profonda di un simulacro in scala 1:1 di Cortina Idrofonica. Il modello è stato realizzato in sezioni componibili fino a raggiungere una lunghezza massima compatibile con l'impianto sperimentale di 142 m. Le diverse configurazioni intermedie provate, a lunghezza crescente, hanno permesso di ottenere con buona approssimazione una previsione di resistenza della cortina vera, lunga 192 metri, per estrapolazione in lunghezza. La forza necessaria a trainare la cortina a 9 m/s in mare risulta essere pari a 2600 N. Il secondo obiettivo raggiunto è stato quello di determinare il tiro della cortina sul modello in scala di VDS nelle successive prove di assetto al canale di circolazione. La forza che può simulare la presenza della cortina è stata qui determinata individuando una linea di correlazione del coefficiente di resistenza, applicabile quindi per qualsiasi scala. Infine l'incertezza composta uc, valutata a 5 m/s nella configurazione solo cortina, risulta essere uguale allo 0.9% della misura.
Cortina Idrofonica
Rimorchio
File in questo prodotto:
File Dimensione Formato  
prod_364409-doc_120187.pdf

solo utenti autorizzati

Descrizione: Prove di Traino su modello di Cortina Idrofonica, Rapporto di Prova n° C.2605-15CT15-RAP01, TESTS No. 1 ÷ 6
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 4.6 MB
Formato Adobe PDF
4.6 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
prod_364409-doc_120188.pdf

solo utenti autorizzati

Descrizione: TR n° C.2605-15CT15-RAP01_Appendice E
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 473.81 kB
Formato Adobe PDF
473.81 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
prod_364409-doc_145641.pdf

solo utenti autorizzati

Descrizione: Rapporto di Prova n° C.2605-15CT15-RAP01, TESTS No. 1 ÷ 6
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 4.08 MB
Formato Adobe PDF
4.08 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/333863
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact