This work instructions note gives the procedure for dimensional check of SPIDER BS accelerator after delivery on - site. The aim of this operation is to verify whether the main accelerator flanges have moved during the transportation of the BS from Nancy to Padova, or not. This check is to be carried just after the delivery of the SPIDER Beam Source to RFX.

Procedure for the dimensional check on the positions of the main flanges of the SPIDER grids

Agostinetti P;Degli Agostini F
2017-01-01

Abstract

This work instructions note gives the procedure for dimensional check of SPIDER BS accelerator after delivery on - site. The aim of this operation is to verify whether the main accelerator flanges have moved during the transportation of the BS from Nancy to Padova, or not. This check is to be carried just after the delivery of the SPIDER Beam Source to RFX.
2017
Istituto gas ionizzati - IGI - Sede Padova
Rapporto finale di progetto