This report describes the high voltage tests carried out by Consorzio RFX (CRFX) personnel on the high voltage pipe break to be installed in the SPIDER H2/D2 line and for the MITICA HVD2. The activities reported in this document can be considered as the prosecution of those described in the technical note RFX_SPIDER_TN_401 where a series of pressure and electrical tests on a ceramic insulating break prototype are reported.
Electrical and Pressure Tests on Hydrogen insulating breaks
Fincato M;
2017
Abstract
This report describes the high voltage tests carried out by Consorzio RFX (CRFX) personnel on the high voltage pipe break to be installed in the SPIDER H2/D2 line and for the MITICA HVD2. The activities reported in this document can be considered as the prosecution of those described in the technical note RFX_SPIDER_TN_401 where a series of pressure and electrical tests on a ceramic insulating break prototype are reported.File in questo prodotto:
Non ci sono file associati a questo prodotto.