This procedure establishes how to perform the verification of the em bedded therm ocouples installed in the SPIDER Beam Source (BS). SPIDER BEAM SOURCE THERMAL SENSORS TEST PROCEDURE RFX - SPIDER - IP - 0 0 6 rev. 0 08 / 01 /20 1 8 3 / 5 1. SCOPE This procedure establishes how to perform the verification of the em bedded therm ocouples installed in the SPIDER Beam Source (BS) . 2. PURPOSE This document presents all the activities to be perform ed at the PRIMA site for the verification and tests of the em bedded therm ocouples in the SPIDER Beam Source when this i s outside the SPIDER Vacuum Vessel.
SPIDER BEAM SOURCE THERMAL SENSORS TEST PROCEDURE PBS element 53.SI.A1
Brombin M;Pasqualotto R
2018
Abstract
This procedure establishes how to perform the verification of the em bedded therm ocouples installed in the SPIDER Beam Source (BS). SPIDER BEAM SOURCE THERMAL SENSORS TEST PROCEDURE RFX - SPIDER - IP - 0 0 6 rev. 0 08 / 01 /20 1 8 3 / 5 1. SCOPE This procedure establishes how to perform the verification of the em bedded therm ocouples installed in the SPIDER Beam Source (BS) . 2. PURPOSE This document presents all the activities to be perform ed at the PRIMA site for the verification and tests of the em bedded therm ocouples in the SPIDER Beam Source when this i s outside the SPIDER Vacuum Vessel.File in questo prodotto:
Non ci sono file associati a questo prodotto.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.