The extraction gap, i.e. the gap between the plasma grid and the ext raction grid, has an important influence on the optics of the beam. This note reports the measurements of the extraction gaps measured on the SPIDER beam source at the Fives-Nordon premises on September 6th 2017.

Measurements on the extraction gaps and aperture positions of the SPIDER beam source

Agostinetti P;Degli Agostini F;
2018

Abstract

The extraction gap, i.e. the gap between the plasma grid and the ext raction grid, has an important influence on the optics of the beam. This note reports the measurements of the extraction gaps measured on the SPIDER beam source at the Fives-Nordon premises on September 6th 2017.
2018
Istituto gas ionizzati - IGI - Sede Padova
Rapporto finale di progetto
neutral beam test facility