A microwave backscattering based tomographic imaging technique has been proposed and studied in the literature. This technique is strictly valid only if the first Born approximation is verified. In [6] and [7] the performance of the technique was studied with reference to point scatterers in a homogeneous medium and to small discontinuities in the reflectivity density function of extended two-dimensional weakly scattering bodies, respectively. In [18] some theoretical bounds for the validity of the Born approximation thecniques were derived. The aim of this report is to show the distorsions in the images obtained by means of this thecnique when that approximation is not valid. A computer-aided simulation has been performed in order to find the maximum allowable mismatch of a body with respect to its surroundings while still obtaining images which are useful for the purposes of industrial nondestructive evaluation (NDE).

Moment method simulations applied to performance evaluation for a born approximation microwave tomographic imaging technique

Salerno E
1990

Abstract

A microwave backscattering based tomographic imaging technique has been proposed and studied in the literature. This technique is strictly valid only if the first Born approximation is verified. In [6] and [7] the performance of the technique was studied with reference to point scatterers in a homogeneous medium and to small discontinuities in the reflectivity density function of extended two-dimensional weakly scattering bodies, respectively. In [18] some theoretical bounds for the validity of the Born approximation thecniques were derived. The aim of this report is to show the distorsions in the images obtained by means of this thecnique when that approximation is not valid. A computer-aided simulation has been performed in order to find the maximum allowable mismatch of a body with respect to its surroundings while still obtaining images which are useful for the purposes of industrial nondestructive evaluation (NDE).
1990
Istituto di Scienza e Tecnologie dell'Informazione "Alessandro Faedo" - ISTI
Performance evaluation
Microwave tomography
File in questo prodotto:
File Dimensione Formato  
prod_453251-doc_171777.pdf

accesso aperto

Descrizione: Moment method simulations applied to performance evaluation for a born approximation microwave tomographic imaging technique
Dimensione 7.42 MB
Formato Adobe PDF
7.42 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/398995
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact