The Institute commissioned the six-component balance Remmers R62 for submerged bodies in 1984. The calibration is defined as the operation that, performed under specified conditions, establishes a relation between the quantity values with measurement uncertainties provided by measurement standards and corresponding indications with associated measurement uncertainties, and, in a second step, uses this information to establish a relation for obtaining a measurement result from an indication. INM performed throughout this period different calibrations that, according to the SOP standard procedures, are performed just before the operating conditions on the hull models in the towing tank. The main aim of this paper is to summarize a global analysis of the various calibration results obtained in over 30 years. The use of an adequate technical procedure and a suitable system for the application of the reference loads allowed to provide an estimate of the measurement uncertainty of the balance. The ±1 kN X transducer presents a combined uncertainty uc equal to 0.3N . The highest uncertainty is evaluated for the ±6 kN rated load Z2 transducer, that shows a 3N uncertainty associated with the measurement. A first order interference matrix that links the measurement to the hydrodynamic action (X, Y, Z, MX, MY e MZ) was evaluated too. The diagonal matrix elements diverge from the ideal value of one from dall'1? to 3?, except for the MX component, that deviates by 1%. The strain interferences, that ideally should be equal to zero, diverge from zero of 2? to 1.5%, with the exception of MX component again.
L'Istituto ha acquisito la bilancia R62 per prove su corpi immersi nel 1984. La taratura è definita come l'operazione che, eseguita in condizioni specificate, stabilisce la relazione tra i valori di una grandezza fisica forniti da campioni di misura e le corrispondenti indicazioni, comprensivi delle incertezze di misura associate, ed usa queste informazioni in una seconda fase per ottenere un risultato di misura a partire da una indicazione. L'Istituto ha eseguito nel tempo diverse campagne di taratura che, secondo procedure operative standard SOP, sono effettuate prima della prova vera e propria sul modello fisico in bacino. Scopo principale di questo lavoro è presentare un'analisi globale dei risultati delle varie tarature effettuate in oltre 30 anni. L'utilizzo di una procedura tecnica adeguata e di un sistema idoneo di applicazione dei carichi hanno permesso di fornire una stima dell'incertezza di misura della bilancia. La componente X ha un'incertezza composta uc di 0.3N per il trasduttore da ±1 kN. La valutazione di incertezza più alta si è avuta per la Z2 da ±6 kN, con una u di 3N. È stata anche individuata una matrice di interferenza che lega fra di loro le misure delle sei componenti dell'azione idrodinamica (X, Y, Z, Mx, My e Mz). I termini diagonali hanno uno scostamento dal caso ideale pari a uno che vanno dall'1 al 3?, eccetto per la componente MX che si discosta dell'1%. Le interferenze, che nel caso ideale di sistema di rigidezza infinita dovrebbero essere pari a zero, si discostano dal 2? all'1.5%, ancora con l'eccezione del momento Mx.
R 62 bilancia a 6-componenti K&R per corpi immersi - taratura
Palini Massimo;Basti Roberto;Olivieri Flavio;Di Cio' Franco
2020
Abstract
The Institute commissioned the six-component balance Remmers R62 for submerged bodies in 1984. The calibration is defined as the operation that, performed under specified conditions, establishes a relation between the quantity values with measurement uncertainties provided by measurement standards and corresponding indications with associated measurement uncertainties, and, in a second step, uses this information to establish a relation for obtaining a measurement result from an indication. INM performed throughout this period different calibrations that, according to the SOP standard procedures, are performed just before the operating conditions on the hull models in the towing tank. The main aim of this paper is to summarize a global analysis of the various calibration results obtained in over 30 years. The use of an adequate technical procedure and a suitable system for the application of the reference loads allowed to provide an estimate of the measurement uncertainty of the balance. The ±1 kN X transducer presents a combined uncertainty uc equal to 0.3N . The highest uncertainty is evaluated for the ±6 kN rated load Z2 transducer, that shows a 3N uncertainty associated with the measurement. A first order interference matrix that links the measurement to the hydrodynamic action (X, Y, Z, MX, MY e MZ) was evaluated too. The diagonal matrix elements diverge from the ideal value of one from dall'1? to 3?, except for the MX component, that deviates by 1%. The strain interferences, that ideally should be equal to zero, diverge from zero of 2? to 1.5%, with the exception of MX component again.File | Dimensione | Formato | |
---|---|---|---|
prod_424894-doc_151550.pdf
accesso aperto
Descrizione: R 62 bilancia a 6-componenti K&R per corpi immersi - taratura
Licenza:
Creative commons
Dimensione
1.92 MB
Formato
Adobe PDF
|
1.92 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.