This document reports the results of the tests on the performances of components suitable for the realization of Optical Emission Spectroscopy diagnostics in MITICA, SPIDER and NIO1. In particular, 2 spectrometers and a 2D CCD detector were tested. The results have then been compared with the requirements of the diagnostic for each experiment.

Test bench of the candidate cameras and spectrometers for the OES in NIO1, SPIDER and MITICA

Barbisan, Marco
;
2012

Abstract

This document reports the results of the tests on the performances of components suitable for the realization of Optical Emission Spectroscopy diagnostics in MITICA, SPIDER and NIO1. In particular, 2 spectrometers and a 2D CCD detector were tested. The results have then been compared with the requirements of the diagnostic for each experiment.
2012
Istituto per la Scienza e Tecnologia dei Plasmi - ISTP - Sede Secondaria Padova
Rapporto intermedio di progetto
negative ion sources
neutral beam injectors
emission spectroscopy
File in questo prodotto:
File Dimensione Formato  
RFX-SPIDER-TN-219.pdf

solo utenti autorizzati

Tipologia: Versione Editoriale (PDF)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 1.06 MB
Formato Adobe PDF
1.06 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/467888