This document represents deliverable D1.6.1 of the Specific Contract F4E-OFC-531-02 – Neutral Beam Test Facility Diagnostics, Task Order No.2: SPIDER Diagnostics #2 and MITICA Diagnostics #1. The final design of the Cavity Ring Down Spectroscopy (CRDS) diagnostic for SPIDER is reported, in particular the layout with interfaces, technical specification of components, description of integration and test procedures.
Final design & technical specification for procurement and test of Cavity Ring Down Spectroscopy in SPIDER
Barbisan, Marco
2018
Abstract
This document represents deliverable D1.6.1 of the Specific Contract F4E-OFC-531-02 – Neutral Beam Test Facility Diagnostics, Task Order No.2: SPIDER Diagnostics #2 and MITICA Diagnostics #1. The final design of the Cavity Ring Down Spectroscopy (CRDS) diagnostic for SPIDER is reported, in particular the layout with interfaces, technical specification of components, description of integration and test procedures.File in questo prodotto: