In this paper the optimal energy efficiency and high cycle pressure problem in single-stage refrigerating carbon dioxide vapour compressor units operating in transcritical conditions is addressed. Literature approximated solutions to the optimisation problem are analysed and critically discussed. A numerical model for CO2 heat exchangers and refrigerant systems is developed. Different gas coolers are simulated in order to investigate the effect of literature simplifying assumptions on the optimal pressure deter- mination: the analysis showed a strong sensitivity of the gas cooler outlet temperature from the secondary fluid temperature, from its capacity rate and from the heat exchanger geometry. Nevertheless it resulted that approximated solutions obtained considering the carbon dioxide gas cooler outlet temperature as an independent variable behaved better than solutions correlating it to secondary fluid inlet temperature. A commercial refrigeration plant and a heat pump water heater were finally simulated to verify their energy performances when applying literature approximated solutions in presence of an on-board compressor capacity and supply water temperature control respectively. While in the case of the commercial refrigeration plant no major penalisation resulted from the literature approximated solutions simplifying assumptions, the heat pump performance was strongly deteriorated, up to +30%, as a conse- quence of the huge variation in the water capacity flow rate resulting from the water temperature control. It was finally concluded that an approximated correlation should be critically evaluated before implementation; a real-time algorithm for determining the optimal (or quasi-optimal) pressure value could provide a more efficient and robust solution.

A critical approach to the determination of optimal heat rejection pressure in transcritical systems

Silvia Minetto
2010

Abstract

In this paper the optimal energy efficiency and high cycle pressure problem in single-stage refrigerating carbon dioxide vapour compressor units operating in transcritical conditions is addressed. Literature approximated solutions to the optimisation problem are analysed and critically discussed. A numerical model for CO2 heat exchangers and refrigerant systems is developed. Different gas coolers are simulated in order to investigate the effect of literature simplifying assumptions on the optimal pressure deter- mination: the analysis showed a strong sensitivity of the gas cooler outlet temperature from the secondary fluid temperature, from its capacity rate and from the heat exchanger geometry. Nevertheless it resulted that approximated solutions obtained considering the carbon dioxide gas cooler outlet temperature as an independent variable behaved better than solutions correlating it to secondary fluid inlet temperature. A commercial refrigeration plant and a heat pump water heater were finally simulated to verify their energy performances when applying literature approximated solutions in presence of an on-board compressor capacity and supply water temperature control respectively. While in the case of the commercial refrigeration plant no major penalisation resulted from the literature approximated solutions simplifying assumptions, the heat pump performance was strongly deteriorated, up to +30%, as a conse- quence of the huge variation in the water capacity flow rate resulting from the water temperature control. It was finally concluded that an approximated correlation should be critically evaluated before implementation; a real-time algorithm for determining the optimal (or quasi-optimal) pressure value could provide a more efficient and robust solution.
2010
Istituto per le Tecnologie della Costruzione - ITC
CO2
Transcritical cycle
Optimisation
Refrigeration
Heat pump
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/11319
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 67
social impact