For the electron cyclotron resonance heating (ECRH) system on the frascati tokamak upgrade (FTU), composed of four 0.5 MW gyrotrons pulsed for 0.5 s, two different calorimetric loads were designed to measure the mm-wave power at 140 GHz propagating either as a gaussian beam or as an HE(11) mode carried by an oversized corrugated waveguide. The first one, designed for low reflectivity and I MW power handling capability, is now routinely used for gyrotron testing, conditioning and optimization on the generator side of the transmission line at 500 kW, 0.5 s. The basic design of the load, with a substantial upgrading of the cooling system for adequate heat removal, has full CW operation capability. The other one, whose cylindrical shape allows positioning as a waveguide replacement, is occasionally used when tests on the transmitted power along the 40 m of waveguide are needed. The loads are described together with low power measurements of reflected radiation. (C) 2001 Elsevier Science BN. All rights reserved.

Calorimetric loads for high power transmission lines at millimeter wavelengths

Bruschi A;Gandini F;Muzzini V;Spinicchia N;Cirant S;Gittini G;Granucci G;Mellera V;Nardone A;Simonetto A;Sozzi C
2001

Abstract

For the electron cyclotron resonance heating (ECRH) system on the frascati tokamak upgrade (FTU), composed of four 0.5 MW gyrotrons pulsed for 0.5 s, two different calorimetric loads were designed to measure the mm-wave power at 140 GHz propagating either as a gaussian beam or as an HE(11) mode carried by an oversized corrugated waveguide. The first one, designed for low reflectivity and I MW power handling capability, is now routinely used for gyrotron testing, conditioning and optimization on the generator side of the transmission line at 500 kW, 0.5 s. The basic design of the load, with a substantial upgrading of the cooling system for adequate heat removal, has full CW operation capability. The other one, whose cylindrical shape allows positioning as a waveguide replacement, is occasionally used when tests on the transmitted power along the 40 m of waveguide are needed. The loads are described together with low power measurements of reflected radiation. (C) 2001 Elsevier Science BN. All rights reserved.
2001
Istituto di fisica del plasma - IFP - Sede Milano
Electron cyclotron resonance heating (ECRH)
Frascati tokamak upgrade (FTU)
Gaussian beam
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/120306
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 17
  • ???jsp.display-item.citation.isi??? ND
social impact