Click evoked otoacoustic emissions (CEOAEs), pure-tone audiograms (PTAs), and Bekesy sweep frequency audiograms were recorded from 15 ears of 11 subjects with noise-induced hearing loss. For all ears, hearing threshold levels >= 30 dB HL were found at the high frequencies. The aims of the study were to examine whether the decomposition of CEOAEs into narrow band components could identify hearing loss in a frequency-specific manner and to what extent audiometric thresholds could be predicted. CEOAEs were parcelled into 0.5-kHz-wide components by means of the wavelet transform. Reproducibility of CEOAE components was compared with audiometric threshold at corresponding frequencies. A general trend of low reproducibility for increasing audiometric thresholds was found. A reproducibility value of 60 per cent was found to best separate normal and elevated thresholds. The presence of a CEOAE component at a given frequency was always associated with audiometric thresholds <= 20-25 dB HL. On the other hand, the absence of a component was equally associated either with normal or abnormal hearing levels. Large inter-subject variability was observed. A weak linear relationship was found between reproducibility and audiometric thresholds at corresponding frequencies, indicating that analysis of narrow band CEOAE components is valuable for separating normal from hearing-impaired ears but cannot replace the audiogram.

Frequency-specific information from click evoked otoacoustic emissions in noise-induced hearing loss

Tognola G;Grandori F;Ravazzani P;
1999

Abstract

Click evoked otoacoustic emissions (CEOAEs), pure-tone audiograms (PTAs), and Bekesy sweep frequency audiograms were recorded from 15 ears of 11 subjects with noise-induced hearing loss. For all ears, hearing threshold levels >= 30 dB HL were found at the high frequencies. The aims of the study were to examine whether the decomposition of CEOAEs into narrow band components could identify hearing loss in a frequency-specific manner and to what extent audiometric thresholds could be predicted. CEOAEs were parcelled into 0.5-kHz-wide components by means of the wavelet transform. Reproducibility of CEOAE components was compared with audiometric threshold at corresponding frequencies. A general trend of low reproducibility for increasing audiometric thresholds was found. A reproducibility value of 60 per cent was found to best separate normal and elevated thresholds. The presence of a CEOAE component at a given frequency was always associated with audiometric thresholds <= 20-25 dB HL. On the other hand, the absence of a component was equally associated either with normal or abnormal hearing levels. Large inter-subject variability was observed. A weak linear relationship was found between reproducibility and audiometric thresholds at corresponding frequencies, indicating that analysis of narrow band CEOAE components is valuable for separating normal from hearing-impaired ears but cannot replace the audiogram.
1999
Istituto di Elettronica e di Ingegneria dell'Informazione e delle Telecomunicazioni - IEIIT
INGEGNERIA BIOMEDICA
Wavelet transform; Click evoked otoacoustic emissions (CEOAE); Narrow band components; Sensorineural hearing loss
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/121744
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 15
social impact