The discrimination of viral and bacterial sepsis is an important issue in intensive care patients. For this purpose, the simultaneous measurements of different analytes are necessary. Among the possible candidates, C-reactive protein (CRP) and procalcitonin (PCT) are probably the most important ones. A novel optical platform was designed and realised for the implementation of fluorescence-based immunoassays. The core of the optical platform is a plastic biochip, constituted by 13 microchannels (50 ?m high, 600 ?m width, 10 mm long) through which the sample flows. The sensing layer, where the immunochemical reaction takes place, is located on the upper part of each microchannel. The chip is interrogated with a novel optoelectronic platform, based on fluorescence anisotropy. A line-shaped beam from a 635-nm laser-diode excites perpendicularly the sensing layer and great many of the emitted remains entrapped inside the chip. The particular shape of the top of the chip allows to guide the emitted fluorescence along the same direction of the microchannel. The fluorescence which comes out on the lateral side from the chip is collected by a single plastic optical fibre and sent to an amplified photodiode. The device was characterised by the implementation of the sandwich assay for CRP and PCT spiked in serum. Limit of quantifications of 4.5 and of 6 ?g L-1 in serum solution were achieved for CRP and PCT, respectively.

Point of care optical device for sepsis diagnosis

A Giannetti;C Trono
2009

Abstract

The discrimination of viral and bacterial sepsis is an important issue in intensive care patients. For this purpose, the simultaneous measurements of different analytes are necessary. Among the possible candidates, C-reactive protein (CRP) and procalcitonin (PCT) are probably the most important ones. A novel optical platform was designed and realised for the implementation of fluorescence-based immunoassays. The core of the optical platform is a plastic biochip, constituted by 13 microchannels (50 ?m high, 600 ?m width, 10 mm long) through which the sample flows. The sensing layer, where the immunochemical reaction takes place, is located on the upper part of each microchannel. The chip is interrogated with a novel optoelectronic platform, based on fluorescence anisotropy. A line-shaped beam from a 635-nm laser-diode excites perpendicularly the sensing layer and great many of the emitted remains entrapped inside the chip. The particular shape of the top of the chip allows to guide the emitted fluorescence along the same direction of the microchannel. The fluorescence which comes out on the lateral side from the chip is collected by a single plastic optical fibre and sent to an amplified photodiode. The device was characterised by the implementation of the sandwich assay for CRP and PCT spiked in serum. Limit of quantifications of 4.5 and of 6 ?g L-1 in serum solution were achieved for CRP and PCT, respectively.
2009
Istituto di Fisica Applicata - IFAC
Inglese
20th International Conference on Optical Fibre Sensors
20th International Conference on Optical Fibre Sensors
75037J-1
75037J-4
4
Sì, ma tipo non specificato
5-9 Ooctober 2009
Edinburgh,Scotland
optical biochip
procalcitonin
C-reactive protein
fluorescence anisotropy
point of care
6
none
Baldinia, F; Bolzoni, L; Giannetti, A; Porro, G; Senesi, F; Trono, C
273
info:eu-repo/semantics/conferenceObject
04 Contributo in convegno::04.01 Contributo in Atti di convegno
   Healthcare by biosensor measurements and networking
   CARE-MAN
   FP6
   17333
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/122203
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact