A new software package for quantitative electron diffraction data treatment of unknown structures is described. No "a priori" information is required by the package which is able to perform in successive steps the 2-D indexing of digitised diffraction patterns, the extraction of the intensity of the collected reflections and the 3-D indexing of all recorded patterns, giving as results the lattice parameters of the investigated structure and a series of data files (one for each diffraction pattern) containing the measured intensities and the relative e.s.d.s of the 3-D indexed reflections. The software package is mainly conceived for the treatment of diffraction patterns taken with a Gatan CCD Slow-Scan Camera, but it can also deal with generic digitised plates. The program is designed to extract intensity data suitable for structure solution techniques in electron crystallography. The integration routine is optimised for a correct background evaluation, a necessary condition to deal with weak spots of irregular shape and an intensity just above the background.

QED V 1.0: a software package for quantitative electron diffraction data treatment

A Migliori
2000

Abstract

A new software package for quantitative electron diffraction data treatment of unknown structures is described. No "a priori" information is required by the package which is able to perform in successive steps the 2-D indexing of digitised diffraction patterns, the extraction of the intensity of the collected reflections and the 3-D indexing of all recorded patterns, giving as results the lattice parameters of the investigated structure and a series of data files (one for each diffraction pattern) containing the measured intensities and the relative e.s.d.s of the 3-D indexed reflections. The software package is mainly conceived for the treatment of diffraction patterns taken with a Gatan CCD Slow-Scan Camera, but it can also deal with generic digitised plates. The program is designed to extract intensity data suitable for structure solution techniques in electron crystallography. The integration routine is optimised for a correct background evaluation, a necessary condition to deal with weak spots of irregular shape and an intensity just above the background.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/124207
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact