Arrays of thermopile detectors arranged on flat panels were used to measure stray radiation from high-power transmission lines at 140 GHz in the FTU tokamak electron cyclotron resonance heating experiment. These instruments are insensitive to polarization and to the direction of propagation within +/-40 degrees off normal incidence. They have a time constant of 120 ms, therefore amplification and synchronous detection are required for the measurement of short radiation pulses. No special measurement techniques are required with long pulses or cw radiation. The typical sensitivity is 2 mV cm(2)/mW in long pulse operation and 47 mu V cm(2)/mW for 1 ms pulses. The detectors are sensitive to light and adequate filtering should be added to suppress it if necessary. These characteristics are adequate for the measurement of human exposure levels to electromagnetic radiation in the millimeter wave range. (C) 1996 American Institute of Physics.

An inexpensive instrument to detect radio-frequency leakage from transmission lines at millimeter wavelengths for personnel safety

Simonetto A;Muzzini V;Bruschi A;Cirant S;Granucci G;Sozzi C
1996

Abstract

Arrays of thermopile detectors arranged on flat panels were used to measure stray radiation from high-power transmission lines at 140 GHz in the FTU tokamak electron cyclotron resonance heating experiment. These instruments are insensitive to polarization and to the direction of propagation within +/-40 degrees off normal incidence. They have a time constant of 120 ms, therefore amplification and synchronous detection are required for the measurement of short radiation pulses. No special measurement techniques are required with long pulses or cw radiation. The typical sensitivity is 2 mV cm(2)/mW in long pulse operation and 47 mu V cm(2)/mW for 1 ms pulses. The detectors are sensitive to light and adequate filtering should be added to suppress it if necessary. These characteristics are adequate for the measurement of human exposure levels to electromagnetic radiation in the millimeter wave range. (C) 1996 American Institute of Physics.
1996
Istituto di fisica del plasma - IFP - Sede Milano
OCCUPATIONAL SAFETY
POWER TRANSMISSION LINES
MICROWAVE RADIATION
LEAK DETECTORS
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/124447
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? ND
social impact