In RFX a monitor for the measurement of the on-axis electron temperature with high temporal resolution has been designed and operated during the last experimental campaigns. It consists of four soft x-ray (SXR) diodes which observe the plasma through four beryllium filters of different thickness. In this article the main design issues are presented. The measured values of the temperature, computed both with the standard double foil method and with a fit of all the available signals, are reported, correlated with the main plasma parameters and briefly compared with the results of other diagnostics. The main causes of systematic error, the effect of the noise and the reliability of the results in various plasma conditions have been investigated. Dynamic evaluations of the temperature up to a maximum bandwidth of 5 kHz are described, confirming the potentialities of the technique to follow fast phenomena. Possible improvements of the diagnostic and future developments are also pointed out.

An optimized multifoil soft x-ray spectrometer for the determination of the electron temperature with high time resolution

A Murari;R Bartiromo;L Carraro;L Marrelli;R Pasqualotto;M Valisa
1999

Abstract

In RFX a monitor for the measurement of the on-axis electron temperature with high temporal resolution has been designed and operated during the last experimental campaigns. It consists of four soft x-ray (SXR) diodes which observe the plasma through four beryllium filters of different thickness. In this article the main design issues are presented. The measured values of the temperature, computed both with the standard double foil method and with a fit of all the available signals, are reported, correlated with the main plasma parameters and briefly compared with the results of other diagnostics. The main causes of systematic error, the effect of the noise and the reliability of the results in various plasma conditions have been investigated. Dynamic evaluations of the temperature up to a maximum bandwidth of 5 kHz are described, confirming the potentialities of the technique to follow fast phenomena. Possible improvements of the diagnostic and future developments are also pointed out.
1999
Istituto gas ionizzati - IGI - Sede Padova
File in questo prodotto:
File Dimensione Formato  
prod_227264-doc_81694.pdf

solo utenti autorizzati

Descrizione: An optimized multifoil soft x-ray spectrometer for the determination of the electron temperature
Dimensione 386.3 kB
Formato Adobe PDF
386.3 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/124645
Citazioni
  • ???jsp.display-item.citation.pmc??? ND