Assessment of iron overload in liver by T2* magnetic resonance imaging (MRI) is a widely used clinical procedure. In the common clinical practice, measurement is performed locally by manually drawing a small region of interest in liver. This procedure may be affected by a noticeable intra- and inter-observer variability. In this study, a new approach is proposed that performs a global semiautomatic measurement of T2* involving the whole liver extension. Parenchyma is automatically segmented by an adaptive fuzzy-clustering algorithm. The liver T2* global value is evaluated using a pixel-wise approach by introducing an appropriate signal decay model. The proposed method was tested on a synthetic software model and on MR images acquired from 30 thalassemia major patients. The methods was demonstrated to increase the measure precision in T2* assessment and to significantly reduce the intra- and interobserver variability.

A robust method for assessment of iron overload in liver by magnetic resonance imaging.

Santarelli;M F;Landini;
2007

Abstract

Assessment of iron overload in liver by T2* magnetic resonance imaging (MRI) is a widely used clinical procedure. In the common clinical practice, measurement is performed locally by manually drawing a small region of interest in liver. This procedure may be affected by a noticeable intra- and inter-observer variability. In this study, a new approach is proposed that performs a global semiautomatic measurement of T2* involving the whole liver extension. Parenchyma is automatically segmented by an adaptive fuzzy-clustering algorithm. The liver T2* global value is evaluated using a pixel-wise approach by introducing an appropriate signal decay model. The proposed method was tested on a synthetic software model and on MR images acquired from 30 thalassemia major patients. The methods was demonstrated to increase the measure precision in T2* assessment and to significantly reduce the intra- and interobserver variability.
2007
Istituto di Fisiologia Clinica - IFC
9781424407880
SEGMENTATION
THALASSEMIA
STORES
MRI
File in questo prodotto:
File Dimensione Formato  
prod_226190-doc_59413.pdf

non disponibili

Descrizione: A robust method for assessment of iron
Dimensione 362.06 kB
Formato Adobe PDF
362.06 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/126735
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 10
social impact