Computer simulation is a valid approach to the in vitro study of cardiac hemodynamics and coronary blood flow mimicking a defined number of experimental variables. Mosher et al. studied coronary autoregulation and featured the coronary pressure-flow diagram being the best way of describing coronary vascular reserve. The graphic representation of the relation between instantaneous aortic pressure and coronary blood flow permits to study the different phases of the coronary flow during the cardiac cycle in different circulatory conditions. The purpose of the present work was to reproduce by a computer simulator, hemodynamic and coronary blood flow waveforms obtained during in vivo experiments in two anaesthetised open chest pigs (performed at the Institute of Clinical Physiology in Pisa -Italy). During the experiments, ECG, left ventricular pressure, aortic pressure and left ventricular volume were monitored together with the coronary blood flow.

Coronary blood flow: comparison between in vivo and numerical simulation data

De Lazzari C;Trivella M G
2007

Abstract

Computer simulation is a valid approach to the in vitro study of cardiac hemodynamics and coronary blood flow mimicking a defined number of experimental variables. Mosher et al. studied coronary autoregulation and featured the coronary pressure-flow diagram being the best way of describing coronary vascular reserve. The graphic representation of the relation between instantaneous aortic pressure and coronary blood flow permits to study the different phases of the coronary flow during the cardiac cycle in different circulatory conditions. The purpose of the present work was to reproduce by a computer simulator, hemodynamic and coronary blood flow waveforms obtained during in vivo experiments in two anaesthetised open chest pigs (performed at the Institute of Clinical Physiology in Pisa -Italy). During the experiments, ECG, left ventricular pressure, aortic pressure and left ventricular volume were monitored together with the coronary blood flow.
2007
Istituto di Fisiologia Clinica - IFC
978-88-8080-081-1
Cardiovascular system
Mechanical Circulatory Support
File in questo prodotto:
File Dimensione Formato  
prod_135234-doc_3018.pdf

solo utenti autorizzati

Descrizione: Capitolo11
Dimensione 181.24 kB
Formato Adobe PDF
181.24 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/129036
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact