When using chiral selectors and the partial filling technique in capillary electrophoresis, a suitable and reproducible suppression of the electroosmotic flow is still a challenging issue, and there are a number of reasons to find alternatives to the use of covalently coated capillaries for such a particular application. In this paper, new achiral, neutral, and water-soluble polymers are evaluated as adsorbed polymers for the suppression of electroosmotic flow (EOF) when employing chiral capillary electrophoresis and the partial filling technique. Four chiral selectors, namely a cationic cyclopeptide, vancomycin, human serum albumin and riboflavin binding protein have been chosen for this study and some analytes such as derivatized amino acids, promethazine and prilocaine have been used as test compounds. Reproducibility of migration times, resolution, and selectivity as well as efficiency are reported to critically evaluate the performance of the adsorbed coatings. Results are compared to parallel data obtained with fused-silica and polyvinyl alcohol-coated capillaries.

Evaluation of new adsorbed coatings when applying chiral capillary electrophoresis and the partial filling technique

M Chiari;M Cretich;
2000-01-01

Abstract

When using chiral selectors and the partial filling technique in capillary electrophoresis, a suitable and reproducible suppression of the electroosmotic flow is still a challenging issue, and there are a number of reasons to find alternatives to the use of covalently coated capillaries for such a particular application. In this paper, new achiral, neutral, and water-soluble polymers are evaluated as adsorbed polymers for the suppression of electroosmotic flow (EOF) when employing chiral capillary electrophoresis and the partial filling technique. Four chiral selectors, namely a cationic cyclopeptide, vancomycin, human serum albumin and riboflavin binding protein have been chosen for this study and some analytes such as derivatized amino acids, promethazine and prilocaine have been used as test compounds. Reproducibility of migration times, resolution, and selectivity as well as efficiency are reported to critically evaluate the performance of the adsorbed coatings. Results are compared to parallel data obtained with fused-silica and polyvinyl alcohol-coated capillaries.
File in questo prodotto:
File Dimensione Formato  
prod_227454-doc_55892.pdf

solo utenti autorizzati

Descrizione: Evaluation of new adsorbed coatings when applying chiral capillary electrophoresis and the partial filling technique
Dimensione 181.98 kB
Formato Adobe PDF
181.98 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/130030
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact