To quantify the heterogeneity of contrast enhancement inside left ventricular (LV) cavity, 10 patients were studied by harmonic intermittent power Doppler following venous echo contrast administration. Regions of interest were drawn in the LV cavity along the main axis and transversally to derive time-intensity curves. Signal intensity at plateau (A) significantly decreased along LV longitudinal axis: from apex (48±6 dB), to center (41±7) and base (31±9 dB, p<0.05), while intensity rise (b) was unaltered. A also was lower in proximity of the septum than in the center of LV cavity (p<0.05). Finally, beat-to-beat variability increased with increasing depth. Thus, LV contrast intensity varies despite a uniform concentration of the contrast agent at each time, due to ultrasound attenuation and heterogeneous beam intensity. Parameter b appears more consistent than A in deriving quantitative flow information.

Signal heterogeneity in contrast-enhanced echocardiographic imaging despite unifom concentration of the contrast agent

Ferdeghini;E M;Morales;M A;Rovai;
2002

Abstract

To quantify the heterogeneity of contrast enhancement inside left ventricular (LV) cavity, 10 patients were studied by harmonic intermittent power Doppler following venous echo contrast administration. Regions of interest were drawn in the LV cavity along the main axis and transversally to derive time-intensity curves. Signal intensity at plateau (A) significantly decreased along LV longitudinal axis: from apex (48±6 dB), to center (41±7) and base (31±9 dB, p<0.05), while intensity rise (b) was unaltered. A also was lower in proximity of the septum than in the center of LV cavity (p<0.05). Finally, beat-to-beat variability increased with increasing depth. Thus, LV contrast intensity varies despite a uniform concentration of the contrast agent at each time, due to ultrasound attenuation and heterogeneous beam intensity. Parameter b appears more consistent than A in deriving quantitative flow information.
2002
Istituto di Fisiologia Clinica - IFC
Inglese
A. Murray
Computers in Cardiology 2002
Computers in cardiology 2002
81
84
4
0-7803-7735-4
Sì, ma tipo non specificato
22-25 Sept. 2002
Memphis
Doppler effect
Image analysis
Statistical methods
Ultrasonics
3
none
Ferdeghini; E M; Morales; M A; Rodriguez O; L'Abbate A; Rovai; D
273
info:eu-repo/semantics/conferenceObject
04 Contributo in convegno::04.01 Contributo in Atti di convegno
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/133639
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact