Coherent x-ray diffraction experiments were performed in Fresnel regime, within a line-projection geometry. A planar x-ray waveguide was used to focus coherent cylindrical waves onto a 7.2 m Kevlar fiber, which acts as a phase object for hard x rays. The phase was retrieved, by using a Fourier-based iterative phasing algorithm, consistent with measured diffraction data and known constraints in real space, with a submicrometer spatial resolution.

Phase retrieval in x-ray coherent Fresnel projection geometry diffraction

Liberato De Caro;Cinzia Giannini;Alessia Cedola;Stefano Lagomarsino;
2007

Abstract

Coherent x-ray diffraction experiments were performed in Fresnel regime, within a line-projection geometry. A planar x-ray waveguide was used to focus coherent cylindrical waves onto a 7.2 m Kevlar fiber, which acts as a phase object for hard x rays. The phase was retrieved, by using a Fourier-based iterative phasing algorithm, consistent with measured diffraction data and known constraints in real space, with a submicrometer spatial resolution.
2007
x-ray coherent diffraction; x-ray imaging; x-ray microscopy
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/13554