In this paper the diagnostic systems implemented on the reversed field pinch (RFP) experiment RFX are presented. The paper is mainly concerned with the general engineering aspects and with the development work addressed to meet specific requirements such as immunity to electrical noise, ultrahigh vacuum compatibility, reliability. A general guideline adopted in the development of diagnostics was to use, whenever possible, proven methods, at least for the systems dedicated to the measurement of the most significant parameters. Each section of the paper illustrates a different system, in which the diagnostic constraints and the specific choices derived from the peculiarities of the RFP configuration are discussed. Although the majority of the diagnostic instruments are at present fully developed and operational, some of them, i.e. far-IR polarimeter, microwave reflectometer, soft X-ray and bolometer tomographic system are either under prototype testing or under construction.

RFX diagnostics

V Antoni;L Carraro;P Innocente;S Martini;A Murari;R Pasqualotto;M E Puiatti;P Scarin;M Valisa;
1995

Abstract

In this paper the diagnostic systems implemented on the reversed field pinch (RFP) experiment RFX are presented. The paper is mainly concerned with the general engineering aspects and with the development work addressed to meet specific requirements such as immunity to electrical noise, ultrahigh vacuum compatibility, reliability. A general guideline adopted in the development of diagnostics was to use, whenever possible, proven methods, at least for the systems dedicated to the measurement of the most significant parameters. Each section of the paper illustrates a different system, in which the diagnostic constraints and the specific choices derived from the peculiarities of the RFP configuration are discussed. Although the majority of the diagnostic instruments are at present fully developed and operational, some of them, i.e. far-IR polarimeter, microwave reflectometer, soft X-ray and bolometer tomographic system are either under prototype testing or under construction.
1995
Istituto gas ionizzati - IGI - Sede Padova
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/138953
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 15
  • ???jsp.display-item.citation.isi??? ND
social impact