The design and the performances of an extreme ultraviolet (EUV)spectrometer/monochromator for generation and diagnostics of high-order harmonics of an ultrashort (<30 fs) pulsed laser focused onto a gas jet are presented. The harmonic generation is optimized using an adaptive mirror before the laser focusing stage. A toroidal mirror is used to focus the XUV radiation in an intermediate stage for pump/probe experiments. A grazing-incidence flat-field spectrometer for the 5-75 nm spectral region has been designed: it adopts a stigmatic toroidal mirror and a varied line-space flat grating mounted in converging light. The almost flat stigmatic spectrum is acquired by a 40-mm-diameter microchannel plate intensifier; the whole detector can be moved to scan various portions of the spectrum. Different detectors allow one to acquire both integrated and single shot spectra at 1 kHz repetition rate. The absolute calibration of the spectrometer is provided. The same optical scheme can be applied to the design of a constant deviation angle EUV monochromator by substituting the detector block with an exit slit.

Instrumentation for analysis and utilization of extreme-ultraviolet and soft x-ray high-order harmonics

Poletto L;Bonora S;Villoresi P
2004

Abstract

The design and the performances of an extreme ultraviolet (EUV)spectrometer/monochromator for generation and diagnostics of high-order harmonics of an ultrashort (<30 fs) pulsed laser focused onto a gas jet are presented. The harmonic generation is optimized using an adaptive mirror before the laser focusing stage. A toroidal mirror is used to focus the XUV radiation in an intermediate stage for pump/probe experiments. A grazing-incidence flat-field spectrometer for the 5-75 nm spectral region has been designed: it adopts a stigmatic toroidal mirror and a varied line-space flat grating mounted in converging light. The almost flat stigmatic spectrum is acquired by a 40-mm-diameter microchannel plate intensifier; the whole detector can be moved to scan various portions of the spectrum. Different detectors allow one to acquire both integrated and single shot spectra at 1 kHz repetition rate. The absolute calibration of the spectrometer is provided. The same optical scheme can be applied to the design of a constant deviation angle EUV monochromator by substituting the detector block with an exit slit.
2004
Istituto di fotonica e nanotecnologie - IFN
INFM
CORRECTED CONCAVE GRATINGS; GENERATION; LASER; PULSES; EMISSION; OPTIMIZATION; SPECTROMETER; IONIZATION; HELIUM; FIELDS
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/13997
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 54
social impact