Up today Hamamatsu R3292 is the Position Sensitive Photo Multiplier Tube (PSPMT) with the largest sensitive area (10 cm of diameter). At the same time it has the minimum size for clinical application in Nuclear Medicine. A portable gamma camera was realized, based on 5" PSPMT coupled to a scintillating array. The head has a light weight (15 kg.) spatial resolution resulted better than that of Anger Camera with good linearity response, good energy resolution and FOV coincident with intrinsic one of PSPMT. To optimize gamma camera response two different scintillating arrays were tested: YAP:Ce and CsI (Tl). Their overall size cover all photocathode active area, and crystal pixel size was 2 mm×2 mm. The detection efficiency resulted comparable to that of Anger Camera. The best result was obtained by CsI (Tl) scintillating: an intrinsic spatial resolution of 1.6 mm FWHM and a relative energy resolution of 17% FWHM. With a standard general purpose collimator a spatial resolution of about 2 mm resulted. Some preliminary results were also obtained in breast scintigraphy

Portable gamma camera for clinical use in nuclear medicine

Soluri A;
1996

Abstract

Up today Hamamatsu R3292 is the Position Sensitive Photo Multiplier Tube (PSPMT) with the largest sensitive area (10 cm of diameter). At the same time it has the minimum size for clinical application in Nuclear Medicine. A portable gamma camera was realized, based on 5" PSPMT coupled to a scintillating array. The head has a light weight (15 kg.) spatial resolution resulted better than that of Anger Camera with good linearity response, good energy resolution and FOV coincident with intrinsic one of PSPMT. To optimize gamma camera response two different scintillating arrays were tested: YAP:Ce and CsI (Tl). Their overall size cover all photocathode active area, and crystal pixel size was 2 mm×2 mm. The detection efficiency resulted comparable to that of Anger Camera. The best result was obtained by CsI (Tl) scintillating: an intrinsic spatial resolution of 1.6 mm FWHM and a relative energy resolution of 17% FWHM. With a standard general purpose collimator a spatial resolution of about 2 mm resulted. Some preliminary results were also obtained in breast scintigraphy
1996
INGEGNERIA BIOMEDICA
Inglese
DelGuerra, A
Nuclear Science Symposium, 1996. Conference Record., 1996 IEEE
1996 IEEE Nuclear Science Symposium and Medical Imaging Conference
2
1170
1174
5
0-7803-3535-X
IEEE, 345 E 47TH ST, NY 10017
NEW YORK
STATI UNITI D'AMERICA
Sì, ma tipo non specificato
NOV 02-09, 1996
ANAHEIM, CA
Medical imaging
PSPMT
scintillation crystal
10
none
Pani, R; Pellegrini, R; Scopinaro, F; Denotaristefani, F; Pergola, A; Devincentis, G; Soluri, A; Iacopi, F; Grammatico, A; Delguerra, A
273
info:eu-repo/semantics/conferenceObject
04 Contributo in convegno::04.01 Contributo in Atti di convegno
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/141686
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact