A new small diameter vascular bioprosthesis (2. 0 mm I. D.) has been fabricated spraying a 2% w/v polyurelhane-silicone blend solution and a 1% w/v fibrinogen solution simultaneously, but separately through two ejectors, onto a cylindrical rotating support. In order to cross-link the proteinous component, the formed tube was incubated with a solution of thrombin, factor XIIIa and calcium chloride. DSC analysis of the material confirmed the transformation of fibrinogen into cross-linked fibrin, through the disappearance of a characteristic transition at 90°C present in the nalive fibrinogen and absent in the cross-linked protein. SEM shows a sponge-like structure with macro and microporouses. 20 Bioprostheses have been implanted in the rabbit as by-pass between the abdominal aorta and the left iliac artery and 10 ones have been implanted as a replacement of carotid artery tracts. These preliminary «in vivo» experiments, still in progress, look promising.

Una nuova bioprotesi vascolare di piccolo diametro (2 .0 mm D.I.) è stata prodotta impiegando una miscela in soluzione di poliuretano e silicone al 2% p/v ed una soluzione di fibrinogeno all'1% p/v. Le due soluzioni sono state depositate mediante tecnica "spray" su di un supporto cilindrico rotante; dopo di che la componente proteica e stata reticolata incubando il tubicino cosi formato in una soluzione di trombina, fattore XIIIa e cloruro di calcio. L'analisi calorimetrica differenziale (DSC) del materiale ha confermato la trasformazione del fibrinogeno in fibrina reticolata. La microscopia elettronica a scansione (SEM) mostra una struttura spugnosa con macro e micropori. Venti bioprotesi sono state impiantate nel coniglio come «by-pass» tra l'aorta addominale e l'arteria iliaca di sinistra e dieci in sostituzione di tratti dell'arteria carotidea di destra. Questi esperimenti «in vivo» sono ancora in corso e, sebbene preliminari, sembrano promettenti.

Produzione, caratterizzazione chimico-fisica e preliminare sperimentazione su animale di una nuova bioprotesi vascolare di piccolo diametro

G Soldani;
1987

Abstract

A new small diameter vascular bioprosthesis (2. 0 mm I. D.) has been fabricated spraying a 2% w/v polyurelhane-silicone blend solution and a 1% w/v fibrinogen solution simultaneously, but separately through two ejectors, onto a cylindrical rotating support. In order to cross-link the proteinous component, the formed tube was incubated with a solution of thrombin, factor XIIIa and calcium chloride. DSC analysis of the material confirmed the transformation of fibrinogen into cross-linked fibrin, through the disappearance of a characteristic transition at 90°C present in the nalive fibrinogen and absent in the cross-linked protein. SEM shows a sponge-like structure with macro and microporouses. 20 Bioprostheses have been implanted in the rabbit as by-pass between the abdominal aorta and the left iliac artery and 10 ones have been implanted as a replacement of carotid artery tracts. These preliminary «in vivo» experiments, still in progress, look promising.
1987
Istituto di Fisiologia Clinica - IFC
Una nuova bioprotesi vascolare di piccolo diametro (2 .0 mm D.I.) è stata prodotta impiegando una miscela in soluzione di poliuretano e silicone al 2% p/v ed una soluzione di fibrinogeno all'1% p/v. Le due soluzioni sono state depositate mediante tecnica "spray" su di un supporto cilindrico rotante; dopo di che la componente proteica e stata reticolata incubando il tubicino cosi formato in una soluzione di trombina, fattore XIIIa e cloruro di calcio. L'analisi calorimetrica differenziale (DSC) del materiale ha confermato la trasformazione del fibrinogeno in fibrina reticolata. La microscopia elettronica a scansione (SEM) mostra una struttura spugnosa con macro e micropori. Venti bioprotesi sono state impiantate nel coniglio come «by-pass» tra l'aorta addominale e l'arteria iliaca di sinistra e dieci in sostituzione di tratti dell'arteria carotidea di destra. Questi esperimenti «in vivo» sono ancora in corso e, sebbene preliminari, sembrano promettenti.
File in questo prodotto:
File Dimensione Formato  
prod_230766-doc_57504.pdf

accesso aperto

Descrizione: Produzione, caratterizzazione chimico-fisica e preliminare sperimentazione su animale di una nuova bioprotesi vascolare di piccolo diametro
Dimensione 956.93 kB
Formato Adobe PDF
956.93 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/142498
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact