The present study investigated myocardial T2* heterogeneity in thalassaemia major (TM) patients by cardiac magnetic resonance (CMR), to determine whether is related to inhomogeneous iron overload distribution. A total of 230 TM patients consecutively referred to our laboratory were studied retrospectively. Three short-axis views (basal, medium and apical) of the left ventricle (LV) were obtained by multislice multiecho T2* CMR. T2* segmental distribution was mapped on a 16-segment LV model. The level of heterogeneity of the T2* segmental distribution, evaluated by the coefficient of variation (CoV),was compared with that of a surrogate data set, to determinewhether the inhomogeneous segmental distribution of T2* could be generated by susceptibility artefacts. Susceptibility artefacts offer an explanation for the T2* heterogeneity observed in patientswithout iron overload. In subjectswith global T2* belowthe lower limit of the normal, T2* heterogeneity increased abruptly which could not be xplained by artefactual effects. Some segmental T2* values were below and others above the limit of normal threshold (20ms) in 104 (45%) TM patients. Among these patients, 74% showed a normal T2* global value. In conclusion, a true heterogeneity in the iron overload distribution may be present in TM patients. Heterogeneity seemingly appears in the borderline myocardial iron and stabilizes at moderate to severe iron burden.

Multislice multiecho T2* cardiac magnetic resonance for the detection of heterogeneous myocardial iron distribution in thalassaemia patients

Santarelli MF Santarelli Maria Filomena;
2009

Abstract

The present study investigated myocardial T2* heterogeneity in thalassaemia major (TM) patients by cardiac magnetic resonance (CMR), to determine whether is related to inhomogeneous iron overload distribution. A total of 230 TM patients consecutively referred to our laboratory were studied retrospectively. Three short-axis views (basal, medium and apical) of the left ventricle (LV) were obtained by multislice multiecho T2* CMR. T2* segmental distribution was mapped on a 16-segment LV model. The level of heterogeneity of the T2* segmental distribution, evaluated by the coefficient of variation (CoV),was compared with that of a surrogate data set, to determinewhether the inhomogeneous segmental distribution of T2* could be generated by susceptibility artefacts. Susceptibility artefacts offer an explanation for the T2* heterogeneity observed in patientswithout iron overload. In subjectswith global T2* belowthe lower limit of the normal, T2* heterogeneity increased abruptly which could not be xplained by artefactual effects. Some segmental T2* values were below and others above the limit of normal threshold (20ms) in 104 (45%) TM patients. Among these patients, 74% showed a normal T2* global value. In conclusion, a true heterogeneity in the iron overload distribution may be present in TM patients. Heterogeneity seemingly appears in the borderline myocardial iron and stabilizes at moderate to severe iron burden.
2009
Istituto di Fisiologia Clinica - IFC
Iron overload
cardiac MRI
iron overload
cardiac MRI
multiecho T2*
File in questo prodotto:
File Dimensione Formato  
prod_169518-doc_13731.pdf

solo utenti autorizzati

Descrizione: Articolo Pubblicato
Dimensione 317.93 kB
Formato Adobe PDF
317.93 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/144671
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 44
  • ???jsp.display-item.citation.isi??? 42
social impact