Remotely sensed data, recorded by means of the MIVIS hyperspectral scanner in the framework of the research activity of the CNR Institutes IIA-LARA and IMAA, have been calibrated to reflec-tance values and then quantitatively compared with ground data. A new procedure for radiometric calibration has been defined by utilizing the MIVIS test-bench and applying a wider radiance range with respect to the one provided by the manufacturing company. New calibration curves have been determined and applied in the pre-processing chain. For validation purpose ground spectra were measured during campaign by means of a portable spec-troradiometer. The atmospheric correction has been carried out by implementing an IDL procedure to manage MODTRAN4 input and output cards. MIVIS test data acquired over Passo Corese (Roma) have shown how the new calibration coeffi-cients significantly improve the radiometric accuracy. In particular, in the VIS spectral region the percentage error, with respect to a ground truth spectrum, is about the half of that occurring if the standard calibration coefficients are used.

Laboratory activity for a new procedure of MIVIS calibration and relative validation with test data

Bassani C;Cavalli R M;Madonna F;Palombo A;
2006

Abstract

Remotely sensed data, recorded by means of the MIVIS hyperspectral scanner in the framework of the research activity of the CNR Institutes IIA-LARA and IMAA, have been calibrated to reflec-tance values and then quantitatively compared with ground data. A new procedure for radiometric calibration has been defined by utilizing the MIVIS test-bench and applying a wider radiance range with respect to the one provided by the manufacturing company. New calibration curves have been determined and applied in the pre-processing chain. For validation purpose ground spectra were measured during campaign by means of a portable spec-troradiometer. The atmospheric correction has been carried out by implementing an IDL procedure to manage MODTRAN4 input and output cards. MIVIS test data acquired over Passo Corese (Roma) have shown how the new calibration coeffi-cients significantly improve the radiometric accuracy. In particular, in the VIS spectral region the percentage error, with respect to a ground truth spectrum, is about the half of that occurring if the standard calibration coefficients are used.
2006
Istituto sull'Inquinamento Atmosferico - IIA
Istituto di Metodologie per l'Analisi Ambientale - IMAA
MIVIS
Radiometric calibration
File in questo prodotto:
File Dimensione Formato  
prod_168409-doc_37467.pdf

non disponibili

Descrizione: Laboratory activity for a new procedure of MIVIS calibration and relative validation with test data
Dimensione 548.42 kB
Formato Adobe PDF
548.42 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/150133
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 13
social impact