The enantioseparation of 2-aryloxypropionic acids by capillary electrochromatography was tested on columns with a monolithic stationary phase prepared from silanized fused-silica capillaries (100 mu m I.D.) by in situ copolymerization of glycidyl methacrylate, ethylene glycol dimethacrylate and methyl methacrylate in the presence of formarnide and 1-propanol as the porogen solvents. The porous chiral monolithic stationary phases were prepared by reaction of the epoxy-groups at the surface of the monolith with (+)-1-(4-aminobutyl)-(5R,8S,10R)-terguride. To attain the minimum HETP values for the enantiodiscrimination of 2-phenoxypropionic acid, the influence of the composition of polymerization solution on column total porosity and efficiency was investigated. Optimum mobile phase conditions were found for all analytes tested using acetonitrile-methanol mixtures containing triethylamine and acetic acid as the buffer components. Furthermore, the chemical and mechanical stabilities of the columns were satisfactory, allowing hundreds of analyses.

Enantioseparation of 2-aryloxypropionic acids on chiral porous monolithic columns by capillary electrochromatography. Evaluation of column performance and enantioselectivity.

Sinibaldi M
2006

Abstract

The enantioseparation of 2-aryloxypropionic acids by capillary electrochromatography was tested on columns with a monolithic stationary phase prepared from silanized fused-silica capillaries (100 mu m I.D.) by in situ copolymerization of glycidyl methacrylate, ethylene glycol dimethacrylate and methyl methacrylate in the presence of formarnide and 1-propanol as the porogen solvents. The porous chiral monolithic stationary phases were prepared by reaction of the epoxy-groups at the surface of the monolith with (+)-1-(4-aminobutyl)-(5R,8S,10R)-terguride. To attain the minimum HETP values for the enantiodiscrimination of 2-phenoxypropionic acid, the influence of the composition of polymerization solution on column total porosity and efficiency was investigated. Optimum mobile phase conditions were found for all analytes tested using acetonitrile-methanol mixtures containing triethylamine and acetic acid as the buffer components. Furthermore, the chemical and mechanical stabilities of the columns were satisfactory, allowing hundreds of analyses.
2006
Istituto di Cristallografia - IC
Istituto per i Sistemi Biologici - ISB (ex IMC)
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/154488
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact