"Purpose: To develop a reliable technique for diffusion imaging of the human spinal cord at 1.5 Tesla and to assess potential differences in diffusion anisotropy in cross-sectional images. Materials and Methods: A single-shot echo-planar imaging sequence with double spin-echo diffusion preparation was optimized regarding cerebrospinal fluid artifacts, effective resolution, and contrast-to-noise ratios. Eleven healthy volunteers participated in the study for quantitative characterization of diffusion anisotropy in white matter (WM) and gray matter (GM) by means of two diffusion encoding schemes: octahedral-six-directions for fractional anisotropy (FA) evaluation and orthogonal-three-directions for anisotropy index (AI) calculation. Results: Pulse-trigger gated sequences with optimal matrix size (read X phase = 64 X 32) and b-value (700 s/mm(2)) allowed the acquisition of high-resolved images (voxel Size = 0.9 X 0.9 X 5.0 mm(3)). The GM butterfly shape was recognizable in both AI and FA maps. Both encoding schemes yielded high diffusion anisotropy in dorsal WM (FA = 0.79 +/- 0.07; AI = 0.39 +/- 0.04). Lateral WM showed slightly lower anisotropy (FA 0.69 +/- 0.08; AI = 0.35 +/- 0.03) than dorsal WM. Clearly smaller anisotropy was found in regions containing GM (FA = 0.45 +/- 0.06; AI = 0.21 +/- 0.05). Conclusion: Diffusion anisotropy data of the spinal cord can be obtained in a clinical setting. Its application seems promising for the assessment of neurological disorders."

Water diffusion anisotropy in white and gray matter of the human spinal cord

Capuani, S;
2008

Abstract

"Purpose: To develop a reliable technique for diffusion imaging of the human spinal cord at 1.5 Tesla and to assess potential differences in diffusion anisotropy in cross-sectional images. Materials and Methods: A single-shot echo-planar imaging sequence with double spin-echo diffusion preparation was optimized regarding cerebrospinal fluid artifacts, effective resolution, and contrast-to-noise ratios. Eleven healthy volunteers participated in the study for quantitative characterization of diffusion anisotropy in white matter (WM) and gray matter (GM) by means of two diffusion encoding schemes: octahedral-six-directions for fractional anisotropy (FA) evaluation and orthogonal-three-directions for anisotropy index (AI) calculation. Results: Pulse-trigger gated sequences with optimal matrix size (read X phase = 64 X 32) and b-value (700 s/mm(2)) allowed the acquisition of high-resolved images (voxel Size = 0.9 X 0.9 X 5.0 mm(3)). The GM butterfly shape was recognizable in both AI and FA maps. Both encoding schemes yielded high diffusion anisotropy in dorsal WM (FA = 0.79 +/- 0.07; AI = 0.39 +/- 0.04). Lateral WM showed slightly lower anisotropy (FA 0.69 +/- 0.08; AI = 0.35 +/- 0.03) than dorsal WM. Clearly smaller anisotropy was found in regions containing GM (FA = 0.45 +/- 0.06; AI = 0.21 +/- 0.05). Conclusion: Diffusion anisotropy data of the spinal cord can be obtained in a clinical setting. Its application seems promising for the assessment of neurological disorders."
2008
INFM
Istituto dei Sistemi Complessi - ISC
TENSOR MRI
IN-VIVO
ECHO
COEFFICIENTS
BRAIN
File in questo prodotto:
File Dimensione Formato  
prod_2969-doc_39053.pdf

accesso aperto

Descrizione: Water diffusion anisotropy in white and gray matter of the human spinal cord
Tipologia: Versione Editoriale (PDF)
Licenza: Altro tipo di licenza
Dimensione 1 MB
Formato Adobe PDF
1 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/159083
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 37
  • ???jsp.display-item.citation.isi??? 33
social impact