High-order coreal wavefront analysis was performed in a population of 60 myopic eyes that underwent photorefractive keratectomy. Corneal aberration data over 3, 5, and 7 mm pupils were collected for up to three years after surgery. The optical performance of the anterior cornea was characterized by estimation of the modulation transfer function (MTF) and the point-spread function. The high-order corneal wavefront aberrations were shown to stabilize one year after surgery. Over photopic pupils, after an early slight increase, corneal RMS-high-order aberrations (HOA) tended to decrease toward preoperative values. On the other hand, over mid- and large-pupil sizes, corneal HOA significantly increased compared with the preoperative state, while the optical performance of the cornea was diminished. The MTF ratio showed a distinct decline in the optical quality of postoperative corneas at low and middle spatial frequencies over larger pupils in the range between 6 and 19 c/deg, especially for deeper ablations. (c) 2007 Optical Society of America.

Long-term optical quality of the photoablated cornea

Lombardo G;
2007

Abstract

High-order coreal wavefront analysis was performed in a population of 60 myopic eyes that underwent photorefractive keratectomy. Corneal aberration data over 3, 5, and 7 mm pupils were collected for up to three years after surgery. The optical performance of the anterior cornea was characterized by estimation of the modulation transfer function (MTF) and the point-spread function. The high-order corneal wavefront aberrations were shown to stabilize one year after surgery. Over photopic pupils, after an early slight increase, corneal RMS-high-order aberrations (HOA) tended to decrease toward preoperative values. On the other hand, over mid- and large-pupil sizes, corneal HOA significantly increased compared with the preoperative state, while the optical performance of the cornea was diminished. The MTF ratio showed a distinct decline in the optical quality of postoperative corneas at low and middle spatial frequencies over larger pupils in the range between 6 and 19 c/deg, especially for deeper ablations. (c) 2007 Optical Society of America.
2007
INFM
IN-SITU KERATOMILEUSIS
WAVE-FRONT ABERRATIONS
HIGHER-ORDER ABERRATIONS
RETINAL IMAGE QUALITY
AGE-RELATED-CHANGES
File in questo prodotto:
File Dimensione Formato  
prod_1997-doc_55623.pdf

accesso aperto

Descrizione: Long-term optical quality of the photoablated cornea
Dimensione 377.05 kB
Formato Adobe PDF
377.05 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/161836
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 5
social impact