Despite the increasing interest in arraying proteins in a high-density format, several technical issues still impede the development of protein microarray technology. One of the major problems is the availability of substrates that are able to bind native proteins with high density. In this study, we investigated the suitability of a novel surface as a support for protein microarrays. A polymeric glass coating is obtained by physical adsorption of a N,N-dimethylacrylamide (DMA), N,N-acryloyloxysuceinimide (NAS), and [3-(methacryloyl-oxy)propyl]trimethoxysilyl (MAPS) copolymer. The coating procedure provides a fast and inexpensive method of producing hydrophilic functional surfaces. The slide performance was investigated in a protein-protein interaction experiment and in the assessment of rheumatoid factor (RF) in human serum samples. The results demonstrate that the ligands immobilized on the polymeric surface maintain an active conformation and are easily accessible, providing a detection limit of 54 amol/spot. Moreover, in the RF assay, after hybridization with the sera, the slides have a low background, leading to a detection limit of 900 amol/spot.

A new polymeric coating for protein microarrays

Cretich M;Damin F;Chiari M
2004

Abstract

Despite the increasing interest in arraying proteins in a high-density format, several technical issues still impede the development of protein microarray technology. One of the major problems is the availability of substrates that are able to bind native proteins with high density. In this study, we investigated the suitability of a novel surface as a support for protein microarrays. A polymeric glass coating is obtained by physical adsorption of a N,N-dimethylacrylamide (DMA), N,N-acryloyloxysuceinimide (NAS), and [3-(methacryloyl-oxy)propyl]trimethoxysilyl (MAPS) copolymer. The coating procedure provides a fast and inexpensive method of producing hydrophilic functional surfaces. The slide performance was investigated in a protein-protein interaction experiment and in the assessment of rheumatoid factor (RF) in human serum samples. The results demonstrate that the ligands immobilized on the polymeric surface maintain an active conformation and are easily accessible, providing a detection limit of 54 amol/spot. Moreover, in the RF assay, after hybridization with the sera, the slides have a low background, leading to a detection limit of 900 amol/spot.
2004
Istituto di Chimica del Riconoscimento Molecolare - ICRM - Sede Milano
File in questo prodotto:
File Dimensione Formato  
prod_17198-doc_7499.pdf

non disponibili

Descrizione: articolo
Dimensione 544.59 kB
Formato Adobe PDF
544.59 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/163438
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact