In this work we synthesized new MD1-based poly(ether)urethanes (PEUs) with phospholipid-like residue as chain extender Polymers were prepared by a conventional two-step solution polymerization procedure using 4,4'-diphenylmethanediisocyanate (MDI) and poly(1,4-butanediol) with 1000 as molecular weight to form prepolymers which were successively polymerized with 1-glycerophosphorylcholine (1-GPC), 2-glycerophosphorylcholine (2-(GPC) or glycerophosphorylserine (GPS) as chain extenders. Two reference polymers bearing 1,4-butandiol (BD) have been also synthesized. The polymers obtained were characterized by Fourier transform infrared spectroscopy (FT-IR), nuclear magnetic resonance (NMR), differential scanning calorimetry DSC) and modulated scanning calorimetry (MDSC). The biocompatibility of synthesized segmented polyurethanes was then investigated by platelet-rich plasma contact studies and related scanning electron microscopy (SEM) photographs for blood compatibility and cytotoxicity assay (MTT test) on material elution to assess the effect of any toxic leachables on cellular viability. Three polymers among all have given very satisfactory results suggesting to investigate more deeply their possible use in biomedical devices.

Synthesis, platelet adhesion and cytotoxicity studies of new glycerophosphoryl-containing polyurethanes

Servi S
2007

Abstract

In this work we synthesized new MD1-based poly(ether)urethanes (PEUs) with phospholipid-like residue as chain extender Polymers were prepared by a conventional two-step solution polymerization procedure using 4,4'-diphenylmethanediisocyanate (MDI) and poly(1,4-butanediol) with 1000 as molecular weight to form prepolymers which were successively polymerized with 1-glycerophosphorylcholine (1-GPC), 2-glycerophosphorylcholine (2-(GPC) or glycerophosphorylserine (GPS) as chain extenders. Two reference polymers bearing 1,4-butandiol (BD) have been also synthesized. The polymers obtained were characterized by Fourier transform infrared spectroscopy (FT-IR), nuclear magnetic resonance (NMR), differential scanning calorimetry DSC) and modulated scanning calorimetry (MDSC). The biocompatibility of synthesized segmented polyurethanes was then investigated by platelet-rich plasma contact studies and related scanning electron microscopy (SEM) photographs for blood compatibility and cytotoxicity assay (MTT test) on material elution to assess the effect of any toxic leachables on cellular viability. Three polymers among all have given very satisfactory results suggesting to investigate more deeply their possible use in biomedical devices.
2007
Istituto di Chimica del Riconoscimento Molecolare - ICRM - Sede Milano
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/167504
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 18
social impact