Allergen microarrays are under development for a component-resolved diagnosis of Type I (IgE-mediated) allergies. Here we report an improved microarray coupled to microfluidics for the detection of allergen specific immunoglobulin E (IgE). The signal intensity for IgE detection in serum has been improved by using glass slides coated with a novel poly[DMA-co-NAS] brush copolymer which is able to immobilize allergens in their native conformation and by carrying out the incubation step in dynamic conditions. The assay, fully automated, was performed in a microcell, using a software-controlled fluidic processor, to bring assay reagents on the surface of the array. Microfluidics turns the binding between serum immunoglobulins and immobilized allergens from a diffusion-limited to a kinetic-limited process by ensuring an efficient mixing of serum samples on the surface of the microarray. As a result of this, the binding of high affinity IgE antibodies is enhanced whereas that of low affinity IgG antibodies, which are present at higher concentration, is impaired paving the way to more accurate and sensitive results.

Detection of allergen specific immunoglobulins by microarrays coupled to microfluidics

Cretich M;Chiari M
2009

Abstract

Allergen microarrays are under development for a component-resolved diagnosis of Type I (IgE-mediated) allergies. Here we report an improved microarray coupled to microfluidics for the detection of allergen specific immunoglobulin E (IgE). The signal intensity for IgE detection in serum has been improved by using glass slides coated with a novel poly[DMA-co-NAS] brush copolymer which is able to immobilize allergens in their native conformation and by carrying out the incubation step in dynamic conditions. The assay, fully automated, was performed in a microcell, using a software-controlled fluidic processor, to bring assay reagents on the surface of the array. Microfluidics turns the binding between serum immunoglobulins and immobilized allergens from a diffusion-limited to a kinetic-limited process by ensuring an efficient mixing of serum samples on the surface of the microarray. As a result of this, the binding of high affinity IgE antibodies is enhanced whereas that of low affinity IgG antibodies, which are present at higher concentration, is impaired paving the way to more accurate and sensitive results.
2009
Istituto di Chimica del Riconoscimento Molecolare - ICRM - Sede Milano
File in questo prodotto:
File Dimensione Formato  
prod_17642-doc_7540.pdf

non disponibili

Descrizione: articolo
Dimensione 499.88 kB
Formato Adobe PDF
499.88 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/168342
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 36
social impact