vascular catheterization is a common procedure in clinical medicine. it is normally performed by a specialist using an X-ray fluoroscopic guide and contrast-media. In the present paper, an image-guided navigation system which indicates a path providing guidance to the desired target inside the vascular tree is described with the aim of reducing the exposure of personnel and patients to X-rays during the catheterization procedure. A 3D model of the patient vascular tree, reconstructed with data collected by an angiography before starting the intervention, is used as a guide map instead of fluoroscopic scans. An accurate spatial correspondence between the body of the patient and the 3D reconstructed vascular model is established and, by means of a position indicator installed over the catheter tip, the real-time position/orientation of the tip is indicated correctly. This paper describes the system and the operational procedures necessary to use the proposed method efficiently during a catheter intervention. Preliminary experimental results on a phantom are also reported. (c) 2007 Elsevier Ireland Ltd. All rights reserved.
Development of an auxiliary system for the execution of vascular catheter interventions with a reduced radiological risk; system description and first experimental results
2007
Abstract
vascular catheterization is a common procedure in clinical medicine. it is normally performed by a specialist using an X-ray fluoroscopic guide and contrast-media. In the present paper, an image-guided navigation system which indicates a path providing guidance to the desired target inside the vascular tree is described with the aim of reducing the exposure of personnel and patients to X-rays during the catheterization procedure. A 3D model of the patient vascular tree, reconstructed with data collected by an angiography before starting the intervention, is used as a guide map instead of fluoroscopic scans. An accurate spatial correspondence between the body of the patient and the 3D reconstructed vascular model is established and, by means of a position indicator installed over the catheter tip, the real-time position/orientation of the tip is indicated correctly. This paper describes the system and the operational procedures necessary to use the proposed method efficiently during a catheter intervention. Preliminary experimental results on a phantom are also reported. (c) 2007 Elsevier Ireland Ltd. All rights reserved.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.