The structural configuration of Xe clusters, obtained by ion implantation in a Si matrix, has been investigated as a function of the temperature by x-ray absorption fine structure spectroscopy. In contrast with previous results, we demonstrate that an accurate analysis of the data, using high order cumulants, gives evidence of Xe fcc nanocrystals at low temperature, even in the as-implanted Si; expansion of the Xe lattice is always found as a function of the temperature, with no appreciable overpressure. We point out that a dramatic modification of these conclusions can be induced by an incorrect analysis using standard symmetrical pair distribution function G(r); for this reason, all the results were checked by x-ray diffraction measurements.
Xe nanocrystals in Si studied by x-ray absorption fine structure spectroscopy
2007
Abstract
The structural configuration of Xe clusters, obtained by ion implantation in a Si matrix, has been investigated as a function of the temperature by x-ray absorption fine structure spectroscopy. In contrast with previous results, we demonstrate that an accurate analysis of the data, using high order cumulants, gives evidence of Xe fcc nanocrystals at low temperature, even in the as-implanted Si; expansion of the Xe lattice is always found as a function of the temperature, with no appreciable overpressure. We point out that a dramatic modification of these conclusions can be induced by an incorrect analysis using standard symmetrical pair distribution function G(r); for this reason, all the results were checked by x-ray diffraction measurements.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.