NMR relaxation time distributions, obtained with laboratory and portable devices, are utilized to characterize the pore-size distributions of building materials coming from the Roman remains of the Greek-Roman Theatre of Taormina. To validate the interpretation of relaxation data in terms of pore-size distribution, comparison of results from standard and in situ NMR experiments with results of the mercury intrusion porosimetry (MIP) has been made. Although the pore-size distributions can be obtained by NMR in terms of either longitudinal (T-1) or transverse (T-2) relaxation times distributions, the shorter duration of the T-2 measurement makes it, in principle, preferable, although the determination of T-2 distributions is not necessarily an easy alternative to finding T-1 distributions. Among other things, the T-2 distribution is almost independent of the inhomogeneity of the magnetic field, while the T-2 distribution is strongly influenced by it. This paper was aimed at answering two questions: what are the validity limits to interpret NMR data in terms of pore-size distributions and whether the portable device can successfully be applied as a non-destructive and non-invasive toot for in situ NMR analysis of building materials, particularly those of Cultural Heritage interest. (C) 2007 Elsevier Inc. All rights reserved.

Validity of NMR pore-size analysis of cultural heritage ancient building materials containing magnetic impurities

2007

Abstract

NMR relaxation time distributions, obtained with laboratory and portable devices, are utilized to characterize the pore-size distributions of building materials coming from the Roman remains of the Greek-Roman Theatre of Taormina. To validate the interpretation of relaxation data in terms of pore-size distribution, comparison of results from standard and in situ NMR experiments with results of the mercury intrusion porosimetry (MIP) has been made. Although the pore-size distributions can be obtained by NMR in terms of either longitudinal (T-1) or transverse (T-2) relaxation times distributions, the shorter duration of the T-2 measurement makes it, in principle, preferable, although the determination of T-2 distributions is not necessarily an easy alternative to finding T-1 distributions. Among other things, the T-2 distribution is almost independent of the inhomogeneity of the magnetic field, while the T-2 distribution is strongly influenced by it. This paper was aimed at answering two questions: what are the validity limits to interpret NMR data in terms of pore-size distributions and whether the portable device can successfully be applied as a non-destructive and non-invasive toot for in situ NMR analysis of building materials, particularly those of Cultural Heritage interest. (C) 2007 Elsevier Inc. All rights reserved.
2007
INFM
POROUS-MEDIA
DIFFUSION
RESONANCE
GRADIENTS
FIELDS
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/169911
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact