The ITER Neutral Beam Injector (NBI) power supply system includes several non-standard components, whose ratings go beyond the present industrial practice. Two of these items, to be procured by Fusion for Energy, are: 1. A -1 MVdc air-insulated Faraday cage, called High Voltage Deck 1 (HVD1), hosting the Ion Source and Extractor Power Supplies (ISEPS) and the associated diagnostics. 2. A -1 MVdc feedthrough, called HVD1-TL Bushing, aimed at connecting the HVD1 to the gas (SF6) insulated Transmission Line (TL), containing inside its High Voltage (HV) conductor all ISEPS power and control cables coming from the HVD1 to be connected to the NBI Ion Source services. The paper deals with the status of the design of the HVD1 and HVD1-TL Bushing, focusing on insulation, mechanical and thermal issues as well as on their integration with the other components of the power supply system. In particular, the insulation issue of the integrated system has been addressed by means of an electrostatic Finite Element (FE) analysis whilst a FE thermal simulation has been carried out to assess the impact of the dissipation of the proposed design of the inner conductors (ISEPS conductors) not actively cooled. Finally, the paper describes the status of procurement strategy and execution.
Design status and procurement activities of the High Voltage Deck 1 and Bushing for the ITER Neutral Beam Injector
Antonio De Lorenzi;Luca Grando;Vanni Toigo
2013
Abstract
The ITER Neutral Beam Injector (NBI) power supply system includes several non-standard components, whose ratings go beyond the present industrial practice. Two of these items, to be procured by Fusion for Energy, are: 1. A -1 MVdc air-insulated Faraday cage, called High Voltage Deck 1 (HVD1), hosting the Ion Source and Extractor Power Supplies (ISEPS) and the associated diagnostics. 2. A -1 MVdc feedthrough, called HVD1-TL Bushing, aimed at connecting the HVD1 to the gas (SF6) insulated Transmission Line (TL), containing inside its High Voltage (HV) conductor all ISEPS power and control cables coming from the HVD1 to be connected to the NBI Ion Source services. The paper deals with the status of the design of the HVD1 and HVD1-TL Bushing, focusing on insulation, mechanical and thermal issues as well as on their integration with the other components of the power supply system. In particular, the insulation issue of the integrated system has been addressed by means of an electrostatic Finite Element (FE) analysis whilst a FE thermal simulation has been carried out to assess the impact of the dissipation of the proposed design of the inner conductors (ISEPS conductors) not actively cooled. Finally, the paper describes the status of procurement strategy and execution.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.