On the Padova PRIMA facility the prototype of the ITER HNBs will be tested in the device called MITICA (Megavolt ITER Injector and Concept Advancement). During Beam operation breakdowns will occur across the accelerator grids and Source components causing transient high voltages between parts normally at low voltages, so stressing the electrical insulation of sensor cables, connectors and feedthroughs. The MITICA electrical model implemented to estimate the characteristics of the voltage transients is here described, with particular emphasis on the feedthroughs, on the source insulation and on the embedded diagnostic system. As severe stresses result with the present design mitigating measures are necessary to avoid damage and maintain proper operation. The solution proposed and supported by the analyses to introduce concentrated capacitances in some critical points turns out to be suitable in terms of electrical effects and of technical compatibility with the main requirements of MITICA environment.

Modeling and analysis of breakdown EMI protection for MITICA insulation and embedded diagnostics

A Pesce;N Pomaro;V Toigo
2013

Abstract

On the Padova PRIMA facility the prototype of the ITER HNBs will be tested in the device called MITICA (Megavolt ITER Injector and Concept Advancement). During Beam operation breakdowns will occur across the accelerator grids and Source components causing transient high voltages between parts normally at low voltages, so stressing the electrical insulation of sensor cables, connectors and feedthroughs. The MITICA electrical model implemented to estimate the characteristics of the voltage transients is here described, with particular emphasis on the feedthroughs, on the source insulation and on the embedded diagnostic system. As severe stresses result with the present design mitigating measures are necessary to avoid damage and maintain proper operation. The solution proposed and supported by the analyses to introduce concentrated capacitances in some critical points turns out to be suitable in terms of electrical effects and of technical compatibility with the main requirements of MITICA environment.
2013
Istituto gas ionizzati - IGI - Sede Padova
ITER
Neutral beam injector
MITICA
Breakdown protection
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/172381
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? ND
social impact