Over the past several years, fiber-optic resonators have been successfully used as mechanical probes by virtue of their intrinsic sensitivity to length changes. In a recent work, we devised a diode-laser system for strain interrogation of a high-finesse fiber Bragg-grating cavity, achieving a 10(-13) resolution in the infrasonic and acoustic frequency ranges, thanks to the exceptional stability of an optical frequency comb (OFC). A Pound-Drever-Hall (PDH) frequency locking technique is implemented for low-noise and wide dynamic range readout of the sensor keeping the interrogating laser always linked to the OFC reference. In this way, the low-frequency strain noisefloor is free from laser noise and possibly limited by thermodynamic phase fluctuations or other thermal effects in the fiber.

Fiber optic resonator sensors based on comb synthesizers

Gagliardi G
2012

Abstract

Over the past several years, fiber-optic resonators have been successfully used as mechanical probes by virtue of their intrinsic sensitivity to length changes. In a recent work, we devised a diode-laser system for strain interrogation of a high-finesse fiber Bragg-grating cavity, achieving a 10(-13) resolution in the infrasonic and acoustic frequency ranges, thanks to the exceptional stability of an optical frequency comb (OFC). A Pound-Drever-Hall (PDH) frequency locking technique is implemented for low-noise and wide dynamic range readout of the sensor keeping the interrogating laser always linked to the OFC reference. In this way, the low-frequency strain noisefloor is free from laser noise and possibly limited by thermodynamic phase fluctuations or other thermal effects in the fiber.
2012
Istituto Nazionale di Ottica - INO
Inglese
Kudryashov A.V. ; Paxton A.H. ; Ilchenko V.S. ; Aschke L. ; Washio K.
Laser Resonators, Microresonators, and Beam Control XIV
Conference on Laser Resonators, Microresonators, and Beam Control XIV
82361E
82361E
6
978-0-8194-8879-4
Sì, ma tipo non specificato
JAN 22-25 2012
San Francisco, CA
Diode laser
strain sensor
fiber Bragg-grating
Fabry-Perot resonator
frequency locking
1
none
Gagliardi, G
273
info:eu-repo/semantics/conferenceObject
04 Contributo in convegno::04.01 Contributo in Atti di convegno
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/173667
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact