In the paper the results of clinical and simulation studies on main haemodynamic parameters were compared. Cardiac output, arterial, atrial and venous pressures were measured in vascular patients during spontaneous breathing and artificial ventilation. Computer simulator was used to model a human cardiovascular system and calculate values of haemodynamic parameters in steady states. Changing intrathoracic pressure, from negative to positive values simulated cardiopulmonary interaction during spontaneous breathing and controlled ventilation. The results of the studies presented in the paper proved that numerical simulation is a very suitable and reliable tool to predict trends of haemodynamic parameters changes. Also the potential influence of mechanical ventilatory support on these parameters may by analysed before application of less or more positive airway pressure. It is an important contribution to the safety and efficacy of ventilatory support in these patients in which high intrathoracic pressure may cause a dramatic drop of cardiac output, venous return and arterial pressure.

In vivo and numerical simulation studies on haemodynamic parameters and cardiopulmonary interaction

De Lazzari C;Clemente F;Ferrari G;
2003

Abstract

In the paper the results of clinical and simulation studies on main haemodynamic parameters were compared. Cardiac output, arterial, atrial and venous pressures were measured in vascular patients during spontaneous breathing and artificial ventilation. Computer simulator was used to model a human cardiovascular system and calculate values of haemodynamic parameters in steady states. Changing intrathoracic pressure, from negative to positive values simulated cardiopulmonary interaction during spontaneous breathing and controlled ventilation. The results of the studies presented in the paper proved that numerical simulation is a very suitable and reliable tool to predict trends of haemodynamic parameters changes. Also the potential influence of mechanical ventilatory support on these parameters may by analysed before application of less or more positive airway pressure. It is an important contribution to the safety and efficacy of ventilatory support in these patients in which high intrathoracic pressure may cause a dramatic drop of cardiac output, venous return and arterial pressure.
2003
Inglese
Ilic D., Borsic M., Butorac J.
International Measurement Conferderation XVII World Congress
XVII IMEKO WORLD CONGRESS
1
4
4
953-7124-00-2
Sì, ma tipo non specificato
22-27 June
Dubrovnic, Croatia
Cardiovascular system
heart failure
Haemodynamic
Numerical model
2
info:eu-repo/semantics/conferenceObject
none
274
04 Contributo in convegno::04.02 Abstract in Atti di convegno
De Lazzari C.; Darowski M.; D'Avino E.; Clemente F.; Mimmo R.; Guaragno M.; Tosti G.; Ferrari G.; Menichetti A.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/173822
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact