The response of a surface acoustic wave (SAW) device towards relative humidity (RH) variations in the range 0-80% has been investigated. The sensor response is very fast and reproducible. The sensitive membrane is a novel organometallic polymer, poly-(bistributylphosphine)-platinum-diethylnylbiphenyl (Pt-DEBP), which has been synthesized and characterized by means of FTIR and XPS measurements.

Organometallic polymer membrane for gas detection applied to a surface acoustic wave sensor

Cinzia Caliendo;Enrico Verona;
1995

Abstract

The response of a surface acoustic wave (SAW) device towards relative humidity (RH) variations in the range 0-80% has been investigated. The sensor response is very fast and reproducible. The sensitive membrane is a novel organometallic polymer, poly-(bistributylphosphine)-platinum-diethylnylbiphenyl (Pt-DEBP), which has been synthesized and characterized by means of FTIR and XPS measurements.
1995
Istituto di Acustica e Sensoristica - IDASC - Sede Roma Tor Vergata
Inglese
25
1-3
670
672
3
http://www.sciencedirect.com/science/article/pii/0925400595851488
Sì, ma tipo non specificato
GAS SENSORS
ORGANOMETALLIC POLYMERS
SURFACE ACOUSTIC WAVE SENSORS
IDS Number: RN870 ISSN: 0925-4005
6
info:eu-repo/semantics/article
262
Caliendo, Cinzia; Verona, Enrico; D'Amico, Arnaldo; Furlani, Anita; Infante, Guido; Vittoria Russo, Maria
01 Contributo su Rivista::01.01 Articolo in rivista
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/174612
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 30
  • ???jsp.display-item.citation.isi??? 22
social impact