A modular numerical model is used to study the interaction, in t m of energetic relationships, between the cardiovascular system and a pneumatic left ventricle assist device (LVAD). me experiments are pefformed in two steps: in the first the left ventricle is characterized, with an open loop model of the circulatory system, computing External Work (EW), Pressure Volume Area (PVA) and Cardiac Mechanical Eflciency (CME) as a function of atrial pressure and peripheral resistance. PVA is compared to EW and CME surfaces respectively. In the second step the same variables are evaluuted, with a closed loop model, assisting synchronously the lefi ventricle with the LVAD and changing two of its control parameters: Driving Pressure (DP) and Systole-Diastole (SD) ratio. me path of the working point is related to the value of the arterial elastance, modified by the LVAD, and only in few points the target to minimize PVA and EW and maximize CME is reached.

A numerical model of the circulatory system for heart assistance simulation: effect of a LVAD on energetic relationships inside the left ventricle

Ferrari G;De Lazzari C;
1993

Abstract

A modular numerical model is used to study the interaction, in t m of energetic relationships, between the cardiovascular system and a pneumatic left ventricle assist device (LVAD). me experiments are pefformed in two steps: in the first the left ventricle is characterized, with an open loop model of the circulatory system, computing External Work (EW), Pressure Volume Area (PVA) and Cardiac Mechanical Eflciency (CME) as a function of atrial pressure and peripheral resistance. PVA is compared to EW and CME surfaces respectively. In the second step the same variables are evaluuted, with a closed loop model, assisting synchronously the lefi ventricle with the LVAD and changing two of its control parameters: Driving Pressure (DP) and Systole-Diastole (SD) ratio. me path of the working point is related to the value of the arterial elastance, modified by the LVAD, and only in few points the target to minimize PVA and EW and maximize CME is reached.
1993
Cardiovascular numerical model
Left ventricular assist device
Energetic ventricular variables
Systole-Diastole ratio
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/175000
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact