Pulsed electric fields are used to permeabilize cell membranes in biotechnology and the clinic. Although molecular and continuum models provide compelling representations of the mechanisms underlying this phenomenon, a clear structural link between the biomolecular transformations displayed in molecular dynamics (MD) simulations and the micro- and macroscale cellular responses observed in the laboratory has not been established. In this paper, plasma membrane electropermeabilization is characterized by exposing Jurkat T lymphoblasts to pulsed electric fields less than 10 ns long (including single pulse exposures), and by monitoring the resulting osmotically driven cell swelling as a function of pulse number and pulse repetition rate. In this way, we reduce the complexity of the experimental system and lay a foundation for gauging the correspondence between measured and simulated values for water and ion transport through electropermeabilized membranes. We find that a single 10 MV/m pulse of 5 ns duration produces measurable swelling of Jurkat T lymphoblasts in growth medium, and we estimate from the swelling kinetics the ion and water flux that follows the electropermeabilization of the membrane. From these observations we set boundaries on the net conductance of the permeabilized membrane, and we show how this is consistent with model predictions for the conductance and areal density of nanoelectropulse-induced lipid nanopores.

Water influx and cell swelling after nanosecond electropermeabilization

Stefania Romeo;
2013

Abstract

Pulsed electric fields are used to permeabilize cell membranes in biotechnology and the clinic. Although molecular and continuum models provide compelling representations of the mechanisms underlying this phenomenon, a clear structural link between the biomolecular transformations displayed in molecular dynamics (MD) simulations and the micro- and macroscale cellular responses observed in the laboratory has not been established. In this paper, plasma membrane electropermeabilization is characterized by exposing Jurkat T lymphoblasts to pulsed electric fields less than 10 ns long (including single pulse exposures), and by monitoring the resulting osmotically driven cell swelling as a function of pulse number and pulse repetition rate. In this way, we reduce the complexity of the experimental system and lay a foundation for gauging the correspondence between measured and simulated values for water and ion transport through electropermeabilized membranes. We find that a single 10 MV/m pulse of 5 ns duration produces measurable swelling of Jurkat T lymphoblasts in growth medium, and we estimate from the swelling kinetics the ion and water flux that follows the electropermeabilization of the membrane. From these observations we set boundaries on the net conductance of the permeabilized membrane, and we show how this is consistent with model predictions for the conductance and areal density of nanoelectropulse-induced lipid nanopores.
2013
Istituto per il Rilevamento Elettromagnetico dell'Ambiente - IREA
osmotic imbalance
ion gradients
permeabilization kinetics
electroporation
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/176846
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact