The ITER heating neutral beam injector, based on 1 MV D- ions, will be tested and optimized in the SPIDER source and MITICA full injector prototypes, using a set of diagnostics not available on ITER. Beam intensity uniformity is required to stay within ±10%, thus beam profile is measured with a complementary set of diagnostics. Among them, visible tomography measures the line of sight (LOS) integrated H? or D? radiation generated by the collisions between fast particles and neutral background molecules, and emitted on a plane perpendicular to the beam. A sufficient number of well arranged LOSs allows a tomographic reconstruction of the 2D beam emission profile, which is proportional to the beam density. On SPIDER the system is equipped with about 3000 LOSs, grouped in 15 fans, and the tomographic algorithm is based on the pixel method. The design of the diagnostic is presented, with description of layout and main components and test of the prototype linear CCD camera.

Design of a visible tomography diagnostic for negative ion RF source SPIDER

R Pasqualotto;M Agostini;M Brombin;G Serianni;C Taliercio;
2013

Abstract

The ITER heating neutral beam injector, based on 1 MV D- ions, will be tested and optimized in the SPIDER source and MITICA full injector prototypes, using a set of diagnostics not available on ITER. Beam intensity uniformity is required to stay within ±10%, thus beam profile is measured with a complementary set of diagnostics. Among them, visible tomography measures the line of sight (LOS) integrated H? or D? radiation generated by the collisions between fast particles and neutral background molecules, and emitted on a plane perpendicular to the beam. A sufficient number of well arranged LOSs allows a tomographic reconstruction of the 2D beam emission profile, which is proportional to the beam density. On SPIDER the system is equipped with about 3000 LOSs, grouped in 15 fans, and the tomographic algorithm is based on the pixel method. The design of the diagnostic is presented, with description of layout and main components and test of the prototype linear CCD camera.
2013
Istituto gas ionizzati - IGI - Sede Padova
Beam diagnostic
Tomography
Neutral beam injector
Negative ion source
Linear CCD camera
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/177300
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 13
social impact